Troubleshooting Chart
The following table lists common Super L VI problems, their causes and their solutions.
Problem
Cause
Solution
Frozen screen pointer 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Screen pointer appears to 
shake or jitter 
 
 
Transducer is in Sleep Mode. 
 
 
Menu Strip is in 
Configuration Mode. 
 
 
Tablet plugged into the 
wrong serial port on the 
computer. 
 
Tablet not powered 
correctly. 
 
Batteries low in transducer. 
 
 
Software application set up 
incorrectly. 
 
 
Another device is connected 
to a COM port that shares 
the same IRQ as the tablet 
COM port (i.e., your tablet is 
connected to COM1 IRQ4 
and your modem is 
connected to COM3 IRQ4). 
 
Tablet is set too close to the 
screen monitor. 
 
Tablet’s frequency setting 
Press any button on the 
transducer. 
 
If the configuration light is 
on, click on the Config/Exit 
key on the Menu Strip. 
 
Is the serial port being used 
correctly identified in your 
software application? 
 
Check that the power cable 
is installed correctly. 
 
Replace the batteries in the 
transducer. 
 
Check that the tablet is 
identified in your software 
application. 
 
Move one of the devices to 
another COM port. Contact 
your system manufacturer 
for assistance in relocating 
the device. 
 
 
 
Move the tablet farther away 
from the screen. 
 
Alternate the transducer’s 