1. Press the or keys to select the required
channel.
2. Press and hold the SQL key. A high beep
will be heardand ‘SILENT’ will appear on the
display.
You may activate CTCSS on as many channels
as you wish except channel 5/35 which is
designated for emergency use.
DISABLING CTCSS ON A CHANNEL
Repeat steps 1 and 2 above. A low beep will be
heard and ‘SILENT’ will disappear.
NOTE:
You will not be able to activate CTCSS if
the CTCSS tone is set to ‘oF’.
SCANNING
OVERVIEW
The TX4600 has a SCAN function that allows
groups of user programmable channels to be
scanned for signals. Channels can be scanned at
20 channels per second. When a signal is found,
scanning will pause on that channel to allow the
signal to be heard, then resume scanning when
the channel is clear again.
SCAN GROUPS
The TX4600 features two scan groups - Open
Scan and Group Scan.
Open Scan
Allows any of the installed channels to be
scanned for activity. If a busy channel is found,
scanning will pause to allow the signal to be
heard. Once the channel has been clear for 5
seconds, scanning will resume automatically.
eg: Scanning channels 1 - 8 in Open Scan
Group Scan
Also allows any of the installed channels to be
scanned for activity, but in addition, it also inserts
your Priority channel into the scan sequence.
This means that your Priority channel will be
monitored regularly while scanning to ensure
that no calls are missed. Any signals received on
your Priority channel will take precedence over
any signals received on the other channels.
2
1
3 4 20 5 6 7 8 20
eg: Scanning channels 1 - 8 with Priority channel
20 in Group Scan.
SELECTING A SCAN GROUP
To preselect a Scan Group
The radio is initially set to Open Scan Mode. Please
refer to the MENU settings on page 21 to change
the Scan Group.
PROGRAMMING SCAN CHANNELS
Your TX4600 is supplied with all 80 UHF CB
channels programmed into the Open Scan
memory. Any channels not needed, can be
removed if required. The Group Scan memory is
empty by default and you will need to add
channels to it before use.
To add or remove Channels from either
Scan Memory
1. Ensure that the radio is not already scanning.
If it is, briefly press the SCAN key to cancel
the scan function.
2. Ensure you have the required scan group
preselected (See MENU settings on page 21).
3. Select the required channel using the or
keys.
• If ‘M’ is visible to the right of the channel
number, the selected channel is already in the
scan memory. It can be removed by holding
the SCAN key in for a few seconds until a
2
1
3 4 5 6 7 8