Duress alarm parameters – FingerTec i-Kiosk 100 Plus Manual User Manual
Page 51
51
1
2
Options available and their functions
LOCK (1-10S)
To adjust the unlocking time after verification.
DSEN. DELAY (1-99S)
To delay door sensor from triggering alarm system
when door is not closing. This function only works
when a door sensor is attached to the reader.
DSEN MODE
To choose the type of door sensor attached to the
reader. There are NO (normally opened) and NC
(normally closed) available. Choose NONE if no door
sensor is attached.
ALARM DELAY (1-99S)
To delay the reader from triggering alarm system.
ALARM COUNT (1-9 TIMES)
To adjust the maximum verification failures of users.
When the maximum is reached, reader will trigger
alarm system.
CLOSE TZ
Door is always locked during the predefined time pe-
riod, so users cannot gain access after verification.
OPEN TZ
Door is always unlocked during the predefined time
period, so users do not need to verify their identities
but can gain access.
VALID HOLIDAYS
Choose Valid to enable the holiday settings. Choose
Invalid to disable the holiday settings.
DURESS ALARM
PARAMETERS
The fingerprint reader will trigger alarm system af-
ter a duress fingerprint is verified successfully. It is
advisable
To use different fingers to do daily clocking
mechanism and to trigger duress alarm
OR
To use different verification to do daily
clocking mechanism and to trigger duress
alarm.