EVCO EC3180 User Manual
Page 4
![background image](/manuals/675564/4/background.png)
WORKING SETPOINT
Label Min. Max. U.m. Stand.
Working setpoint
r1
r2
°
C
+2
working setpoint
CONFIGURATION PARAMETERS
Label Min. Max. U.m. Stand.
Password
PA
-55
99
---
0
password (§)
Label Min. Max. U.m. Stand.
Measure inputs
/0
1
4
---
1
kind of probe
/1
-55
+99
°
C/8
0
calibration
/2
0
6
---
3
digital filter
/3
---
---
---
---
reserved
Label Min. Max. U.m. Stand.
ON-OFF temperature regulator associated to the work-
ing setpoint and to the output K 1
r0
+1
+15
°
C
+2
hysteresis (differential) (§)
r1
-55
+99
°
C
-50
minimum working setpoint programmable
r2
-55
+99
°
C
+50
maximum working setpoint programmable
Label Min. Max. U.m. Stand.
Output K 1 protection
C0
0
15
min.
0
disabling time to the output activation from the instrument start
C1
0
15
min.
5
disabling time to the output activation from the previous activation
C2
0
15
min.
3
disabling time to the output activation from the previous deactiva-
tion
C3
0
1
---
0
output status during a cabinet probe failure alarm
C4
0
1
---
0
disabling time to the output activation and deactivation
Label Min. Max. U.m. Stand.
Defrost regulator
d0
0
99
(*)
8
defrost interval
d1
0
1
---
0
kind of defrost
d2
-55
+99
°
C
+2
defrost stopping setpoint
d3
1
99
(*)
30
defrost maximum length
d4
0
1
---
0
defrost cycle at the instrument start
d5
0
99
(*)
0
delay to a defrost cycle activation from the instrument start
d6
0
1
---
1
locking of the displayed temperature from a defrost cycle activation
d7
0
15
(*)
2
dripping length
d8
0
15
hours
1
disabling time to the temperature alarm activation from the defrost
cycle end
d9
0
1
---
0
disabling times to the output K 1 activation override
dA
---
---
°
C
---
evaporator probe reading (§)
db
0
1
---
0
times base for the parameters d0, d3, d5, d7 and F5
Label Min. Max. U.m. Stand.
Temperature alarm regulator
A0
+1
+15
°
C
+2
hysteresis (differential)
A1
-55
0
°
C
-10
lower alarm set relative to the working setpoint
A2
0
+99
°
C
+10
upper alarm set relative to the working setpoint
A3
0
15
hours
2
disabling time to the alarm activation from the instrument start
A4
---
---
---
---
reserved
Label Min. Max. U.m. Stand.
Evaporator fans regulator associated to the output K 2
F0
0
1
---
1
output functioning
F1
-55
+99
°
C
-1
output deactivation setpoint
F2
+2
+15
°
C
+2
hysteresis (differential)
F3
0
1
---
1
output typology
F4
0
1
---
1
output forced to the status OFF during the defrost
F5
0
15
(*)
15
evaporator fans stoppage length
F6
0
1
---
0
kind of output deactivation setpoint
Label Min. Max. U.m. Stand.
Connection in a serial network with EVCOBUS protocol
communication
L0
---
---
---
---
reserved
L1
1
15
---
1
instrument address
Additional informations:
• the symbol (§) indicates that the parameter is of the first level
• the symbol (*) indicates that the unit of measure depends from the parameter db.