EVCO S.p.A. | Code 104RS235E104 | Page 7 of 10 | PT 07/14 | version 1.0

d4

0

1

- - -

0

0

defrosting when device is switched on (only if d8 = 0, 1, 2 or 3) (4)
1

=

YES

d5

0

99

min

0

0

if d4 = 0, minimum time between switching on of device and activation of defrosting; see also i0 and i5 (4)
if d4 = 1, delay in activation of defrosting after device is switched on ; see also i0 and i5 (4)

d6

0

1

- - -

1

1

temperature displayed during defrosting (only if P5 = 0)
0

=

cabinet temperature or CPT temperature

1

=

if on activation of defrosting, the cabinet temperature or the CPT temperature is below the “work set point + r0”, at
maximum “ work set point + r0”; if on activation of defrosting, the cabinet temperature or the CPT temperature is above
“work set point + r0”, at maximum the cabinet temperature or CPT temperature on activation of defrosting (12)

d7

0

15

min

2

2

dripping duration (during dripping the compressor will remain switched off and the defrosting output will remain deactivated; if d16
= 0, evaporator fan activity will depend on parameter F2; if d16 ¹ 0, the evaporator fan will remain switched off)

d8

0

4

- - -

0

0

defrosting activation methods
0

=

AT INTERVALS - defrosting will be activated once the device has altogether been running for time d0

1

=

AT INTERVALS - FOR COMPRESSOR SWITCH-ON - defrosting will be activated once the compressor has altogether been
switched on for time d0

2

=

AT INTERVALS - FOR EVAPORATOR TEMPERATUREE - defrosting will be activated when the evaporator temperature has
remained below the temperature d9 for a total time of d0 (13)

3

=

ADAPTABLE - defrosting will be activated at intervals, whose duration will each time depend on the duration of compressor
switch-ons and the evaporator temperature; see also d18, d19 and d22 (13)

4

=

IN REAL TIME - (can be set only in EVRS235 model) defrosting will be activated at the times established in parameters Hd1
... Hd6

d9

-99

99,0 °C/°F (1)

0,0

0,0

evaporator temperature is higher than that at which the defrost interval counter is suspended (only if d8 = 2)

d11

0

1

- - -

0

0

defrosting alarm switches off once maximum time limit has been reached (code “dFd”; only if P3 = 1 and in absence of an
evaporator probe (code “Pr2”)
1

=

YES

d15

0

99

min

0

0

minimum time that the compressor must be switched on before defrosting can be activated (only if
d1 = 1) (14)

d16

0

99

min

0

0

predripping duration (during predripping the compressor will remain switched off, the defrosting output will be activated and the
evaporator fan will remain switched off)

d18

0

999

min

40

40

defrosting interval (only if d8 = 3; defrosting will be activated when the compressor has been on totally, with the evaporator
temperature below that of d22, for time d18)
0

=

defrosting will never be activated due to the effect of this condition

d19

0,0

40,0 °C/°F (1)

3,0

3,0

evaporator temperature above which the defrost is activated (relative to the evaporator temperatures average, or “evaporator

temperatures average - d19”) (only if d8 = 3)

d20

0

500

min

180

180

minimum consecutive time the compressor must be switched on such as to provoke the defrost activation
0

=

defrosting will never be activated due to the effect of this condition

d22

0,0

10,0 °C/°F (1)

2,0

2,0

evaporator temperature above which the defrosting interval is suspended (relative to the evaporator temperatures average, or

“evaporator temperatures average + d22”) (only if d8 = 3); also look at d18

d24

0

999

min

30

30

maximum duration of activation of the defrosting synchronisation input due to activation of defrosting (only if i0 = 6)

d25

0

1

- - -

0

0

enabling of the outlet air probe as defrosting probe during the evaporator probe error (code “Pr2”;
only if P4 = 3); see also d26 (15)
1

=

YES

d26

0

99

h

6

6

defrosting interval for effect of enabling of outlet air probe like defrosting probe during evaporator probe error (“Pr2” code; only if
d25 = 1) (11)
0

=

interval defrosting will never be activated

PARAM.

MIN.

MAX.

U.M.

EVRS225 EVRS235 TEMPERATURE ALARMS

A0

0

1

- - -

0

0

temperature associated with the minimum temperature alarm (code “AL”)
0

=

cabinet temperature or CPT temperature

1

=

evaporator temperature (16)

A1

-99

99,0 °C/°F (1) -10,0

-10,0

temperature below that at which the minimum temperature alarm is activated (code “AL”); see also A0, A2 and A11

A2

0

2

- - -

1

1

type of minimum temperature alarm (code “AL”)
0

=

alarm absent

1

=

relative to working set-point (that is “working set-point - A1”; consider A1 without sign)

2

=

absolute (that is A1)

A4

-99

99,0 °C/°F (1) 10,0

10,0

temperature higher than that at which the maximum temperature alarm is activated (code “AH”); see also A5 and A11

A5

0

2

- - -

1

1

type of maximum temperature alarm (code “AH”)
0

=

alarm absent

1

=

relative to working set-point (that is “working set-point + A4”; consider A1 without sign))

2

=

absolute (that is A4)

A6

0

240

min

120

120

delay in maximum temperature alarm (code “AH”) after the device is switched on (4)

A7

0

240

min

15

15

temperature alarm delay(“AL” code and “AH” code)

A8

0

240

min

15

15

delay in maximum temperature alarm (code “AH”) from the conclusion of evaporator fan standstill (17)

A9

0

240

min

15

15

delay in maximum temperature alarm (code “AH”) following the deactivation of the door micro switch input (18)

A10

0

240

min

not avail.

1

duration of a power cut such to cause the power cut alarm to be memorised ( “PF” code)

A11

0,1 (3)

15,0 °C/°F (1)

2,0

2,0

differential of parameters A1and A4

A12

0

2

- - -

not avail.

1

type of power supply cut-off alarm signal (“PF” code);
0

=

alarm will be signalled by the “HACCP” LED

1

=

alarm will be signalled by the “PF” code, the buzzer and the “HACCP” LED

2

=

alarm will be signalled by the “PF” code, buzzer (as long as cut-off duration exceeds time A10) and by the “HACCP” LED

PARAM.

MIN.

MAX.

U.M.

EVRS225 EVRS235 EVAPORATOR FAN AND CONDENSER FAN

F0

0

5

- - -

1

1

evaporator fan activity during normal operation
0

=

switched off

1

=

switched on; see also F13, F14 and i10 (19)

2

=

in parallel with the compressor; see also F9, F13, F14 and i10 (20)

3

=

depending on F1; see also F9, F13 and F14 (22) (23)

4

=

switched off if the compressor is switched off, dependent on F1 if the compressor is switched on; see also F9, F13 and F14
(21) (23)

5

=

with proportional band, see also F20 (it is recommended to set parameter F0 at 5 in case of

F1

-99

99,0 °C/°F (1)

-1,0

-1,0

evaporator temperature above the limit at which the evaporator fan is switched off (only if F0 = 3 or 4); see also F8

F2

0

2

- - -

0

0

evaporator fan activity during defrosting and dripping
0

=

switched off

1

=

switched on (setting parameter d7 to 0 is recommended)

2

=

in case of analogue management, as if F0 = 5
in case of digital management, depending on F0

F3

0

15

min

0

0

maximum duration of evaporator fan deactivation; see also F7 (during evaporator fan deactivation the compressor can be switched
on, the defrosting output will remain deactivated and the evaporator fan will remain switched off)

F7

-99

99,0 °C/°F (1)

5,0

5,0

evaporator temperature below limit at which the evaporator fan is deactivated (relative to working set point, that is “working set
point + F7”); see also F3

F8

0,1 (3)

15,0 °C/°F (1)

2,0

2,0

parameter F1differential

F9

0

240

s

0

0

delay in the switching off of evaporator fan following the switching off of the compressor (only if F0 = 2, 3, 4 and 5)

F11

0,0

99,0 °C/°F (1) 15,0

15,0

temperature of the condenser above which the condenser fan is switched on (“F11 + 2,0 °C/4 °F, only if
u1 and/or u11 = 6) (25) (26)