Water Filter Data
im
System Specification and Performance Data Sheet
S Refrigerator Water Filter Cartridge Model 9005
I
Specifications
Service Flow Rate (Maximum),
Rated Service Life Model 900S (Maximum).
Maximum Operating Temperature
Minimum Pressure Requirement........
Maximum Operating Pressure.......................
075 GPM (2 ,83 L/min)
500 gallons/ 1892 liters
100“ F/38“ C
35 psi/ 138 kPa
120 psI/ 827 kPa
General Use Conditions:
Read this Performance Data Sheet and compare the capabilities of this unit with your actual
water treatment needs ,
DO NOT use this product where water is microbiologicaliy unsafe or of unknown quality without adequate disinfection
before or after the system. System certified for cyst reduction may be used on disinfected water that may contain
filterable cysts.
USE ONLY W!TH COLD WATER SUPPLY. CHECK FOR COMPLIANCE WITH THE STATE AND LOCAL LAWS AND REOULATIONS-
The retractable water filtratiorr system uses a 9005 reptacernent cartridge (see Sears contact information at the front of your
manual to order), Timely replacement of filter cartridge is essential for performance satisfaction from this filtration system.
Please refer to the applicable section in this Use and Care Guide for general operation, maintenance requirements and
troubleshooting,
This systems has been tested according to ANSi/NSF 42 and 53 for reduction of the substances listed
below The concentration of the indicated substances in water entering the system was reduced to a
concentration less than or equal to the permissible limit for water leaving the system, as specified in
ANSI/NSF 42 and 53,,
Performance Data*
Q
r
m
Substance
influent chalienge
concentrslfon
Effluent
Average
Average
%
Reduction
Maximum
Effluent
Min, Required
Reduction
Inlet
pH
L©sd
0.1Smpi+/10%
0.001 mg/L
99.33%
0.001 mg/L
0.010 mg/L
6.5
Lesci
0.15тз1_+/Ю%
0.002 mq/L
98.66%
0.003 ma/L
0.010 mcj/L
8,5
Cyst
№mimS0.CX)QL
Icount/mL
99.99%
3 count/mL
> 99.95%
NA
Turbidity
T1+/-1NTU
0.12 NTU
38,98%
0.18 NTU
0.5 NTU
NA
Lindane
O.OffimaiL+MO%
0,00005 mfl/L
97.62%
O.Q00Q5 mq/L 0.00002 mq/L
NA
Atrazine
0.009 mqL+/-10%
0.0002 mg/L
97.93%
0.0006 mfl/L
0.003 mg/L
NA
Chlorine
20mg/L+/-lO%
0.09 mg/L
95.26%
0,17 mfl/L
?75%
NA
Parilcuiate**
at least 10,000
particles/mL
900 count/mL
99.68%
2400 count/mL
?85%
NA
2,4-0
07t0moL+/10%
45,45 uq/L
84.42%
100 ufl/L
0.0017 mq/L
NA
Asbestos
itf b К/ЛнзЬЬазд®!?!!»
lOtrtcntììs'nisreii
O.IOMFUmL
99.96%
O.I6MFL/mL
99%
NA
Tested using a flow rate of 0,75 GPM (2,83 L/min ) and a maximum pressure of 120 psi (827 kPa)
under standard laboratory conditions, however, actual performance may vary Health Claim
Performance tested and certified by NSF International
Particle size range classification of test Particles used were 0 5-1 microns
Pentapure, incorporated
WOO Apollo Road
Eagan, Minnesota U S A .
BPA ESTm89l7-MN-1
TEEted and CatSisEii by NSF Intenìattobsì agatet ANSi/NSF SiaiKjaitìs
42 à
53 în models ШР50^КН)ЗШ and WFSO-KWiSOO icc
Ш
of:
sancËrd No. 4Z iesSierfflc Etfeds
Stantfani Mo, 53; HeaSb EfTecfe
Teste
&.
Odor ReciudSon
Ghemica) Reducilon Unit
Chkxtne Reduction
Lead, Airszsœ» liTi^aneài 2.4C)
Mechanical Fiteton Unit
Fîlti^îlQn Ubil
Partivate Reduction Class t
Cyst Turtiîdîy- & Asbestos Redudfon