Conventional systems – Braeburn 2200NC User Manual

Page 5

background image

4

Heat Only or Millivolt

Set Installer Switch to NORM

Rh* Power Connection

W Heat Relay (appears as W1/E on 2200NC)

G Fan Relay [note 4]

C 24 Volt AC Transformer Common [note 1]

1 HEAT / 1 COOL Single or Dual Transformer

Set Installer Switch to NORM

Rh* 24 Volt AC Power (heating transformer) [note 2]

Rc* 24 Volt AC Power (cooling transformer) [note 2]

W Heat Relay (appears as W1/E on 2200NC)
Y

Compressor Relay

(appears as

Y1 on 2200NC)

G Fan Relay

C 24 Volt AC Transformer Common [note 1, 3]

Typical Wiring Configurations

NOTE: The “Installer Switch” option will be configured in the next step.

Conventional Systems

24VAC Power
Terminal (C)

NOTES - Conventional Systems

[1] If batteries are installed the 24 Volt AC common connection is optional.
[2] Remove factory installed jumper for dual transformer systems.
[3] In dual transformer systems, transformer common must come from

cooling transformer.

[4] If needed for system.

Provide disconnect and overload protection as required.

2 HEAT / 1 COOL Single Transformer (2200NC Only)

Set System Type to NORM

R

24 Volt AC Power

W1 Heat Relay Stage 1
W2 Heat Relay Stage 2
Y1 Compressor Relay Stage 1
G

Fan Relay

C

24 Volt AC Transformer Common

[note 1]

* Appears as R on 2200NC (single transformer)

.