2

3

Default Thermostat Settings
At initial power up or after Installer

CLEAR is pressed, the thermostat is

reset to factory defaults. Installer

CLEAR is located on the circuit board.

Installation

2

cont.

Installing New Thermostat

NOTE: When installing this thermostat in a new location, following a few simple

guidelines and the applicable building codes will give the best results. Install the

thermostat in a location that provides good airflow by avoiding areas behind doors,

near corners, air vents, direct sunlight or heat generating devices. The wiring must

conform to all building codes and ordinances as required by local and national code

authorities having jurisdiction for this installation.
1. Always turn off the power to the air conditioning and heating system prior to

installing this thermostat.

2. Locate the release latch on the bottom (not the back) of the thermostat. Press

the release latch in and separate the body from the sub-base of the thermostat.

3. Set the thermostat electronics and cover down on a clean surface. Place the

sub-base on the wall in the desired location.

4. Using the slotted mounting holes in the sub-base, mark the placement of the

mounting holes through the slots and onto the wall. Ensure the wires come out

of the wall into the center hole of the sub-base.

5. After verifying the drill will not damage items in the wall, use a 3/16 drill to

create the mounting holes. Gently tap the supplied plastic anchors into the

holes in the wall.

6. Place the thermostat sub-base against the wall in the desired location. Ensure

the thermostat is level, the wires are inserted in the opening, and the mounting

holes are aligned with the slots on the sub-base.

7. Fasten sub-base to wall using the supplied screws into the plastic wall anchors.
8. Connect wires to the quick wiring terminal blocks. Use the wiring diagram chart

to ensure the old and new connections are correct.

9. To prevent electrical shorts and potential damage to the thermostat, make sure

all wire connections are secure and not touching each other.

10. Ensure the cover is still installed on the body, and install them onto the

sub-base. To do so, use the mounting tabs on the top of the sub-base as a

guide hinge, and close up the thermostat case by pivoting the body and cover

closed. The latch on the bottom of the thermostat will click when the case is

properly closed.

11. Flip the front thermostat cover open and open the battery compartment door.
12. Locate the positive [+] ends of the batteries and match them with the positive

[+] terminals located in the battery compartment. Install the two new “AA”

alkaline batteries (supplied). Close battery compartment door.

13. Restore system power and proceed to Programming Installer Settings.

Programming Installer Settings

3

Function

Status After Clear

Temperature Hold

Permanent and Temporary Hold Cleared

Clock

12:00 p.m., Monday

Room Temperature

70˚ F (21.0˚ C), to be renewed within

5 seconds.

Set Point Temperature

According to System Switch

62˚ F (17.0˚ C) for Heat, Emergency Heat & Off

83˚ F (28.0˚ C) for Cool

Temperature Scale

˚F

Operating Program

DAY program, Monday

Low Battery Warning

Off, to be renewed within 5 seconds

AC Interrupted Warning

Off, to be renewed within 5 seconds

1st Stage Differential

0.5˚ F (0.25˚ C)

2nd Stage Differential

2˚ F (1.0˚ C)

Programming

7 Day, 4 Event

Residual Cooling Fan Delay

60 Seconds

Short Cycle Protection Timer On, Reset
Adaptive Recovery Mode

Off

Output Relays

Off

Extended Hold

Indefinite

Filter Check Monitor

0 days-off, Time reset

Keypad Lock

Unlocked

System Type

Conventional, Single Stage

1st Stage Heat Fan Control

Gas

2nd Stage Heat Fan Control

Electric

Fossil Fuel Compressor Lock Off
Outage Protection Timer

Off, reset

AC Interrupt Warning Mode

OFF