Chapter 3: Local Management

3-18

WPIM-RT1 User’s Guide

The line configuration information shown in

Table 3-3

must be supplied

by the service provider.

3.5.1

Frame Relay Physical Configuration

Begin the WPIM-RT1 physical configuration by accessing the WAN
Physical Configuration
screen through Local Management (

Figure 3-1

).

Proceed with the following steps:

1.

Use the arrow keys to highlight the [WPIM X] field at the bottom of
the screen. Press the SPACE bar to select the number of the WPIM to
be configured, then press ENTER.

Use the arrow keys to highlight the MgrType field. Configure Protocol
Manager Type as either FR PtoMP or FR PtoP. There are two settings for
Frame Relay, Point-to-Point (FR PtoP) and Point-to-Multipoint (PtoMP).
Frame Relay Point-to-Point has one Interface per DLCI assigned when
DLCIs are created by the Service Provider. In Frame Relay
Point-to-Multipoint, there is one interface to multiple DLCIs, and the
DLCIs are dynamically learned. Backup can only be run on FR PtoP, not
FR PtoMP.

2.

Use the arrow keys to highlight Timeslot View. Press the SPACE bar
to select New, then press ENTER. The cursor moves to the first
timeslot available in the Timeslot Configuration Table.

Table 3-3

Telco Configuration Information

Configuration Information

Required by Customer

Information Supplied by

Service Provider

Line Coding

B8ZS or AMI

Frame Type

ESF or D4

Clock Source

Loop Timing or Local Timing

DS-0s (Timeslots)

Timeslots being used for each end of
the circuit

NOTE

When changing from one protocol to another on a WPIM-RT1
that has been operational, save NONE as the protocol before
changing to another protocol.