beautypg.com

Figure 3-3 sample configuration – Cabletron Systems WPIM-RT1 User Manual

Page 28

background image

Chapter 3: Local Management

3-6

WPIM-RT1 User’s Guide

Figure 3-3

shows a sample configuration for three sites. Of the 24

Timeslots, Site #1 uses 16 to communicate with Site #2 and the remaining
8 to communicate with Site #3. This configuration varies tremendously
depending on how the service provider maps out the T1 Timeslots. The
service provider indicates which Timeslots are active.

Figure 3-3

Sample Configuration

Site #1 is using the full T1, so all the Timeslots must have an Interface
assignment. Site #2 and Site #3 use only a fraction of the T1, but the total
quantity of Timeslots must match those of Site #1. Unused Timeslots
receive an Interface number of 000.

NOTE

The Interface numbers of Site #1, Site #2 and Site #3 do not
have to match. Only the quantity and position of Timeslots
must match (the service provider assigns the Timeslots).

SITE #2

01-08

09-16

17-24

SITE #3

01-08

09-16

17-24

SITE #1

01-08

09-16

17-24

1482_03

005

005

000

005

005

000

005

005

000

005

005

000

005

005

000

005

005

000

005

005

000

005

005

000

000

000

006

000

000

006

000

000

006

000

000

006

000

000

006

000

000

006

000

000

006

000

000

006

005

005

006

005

005

006

005

005

006

005

005

006

005

005

006

005

005

006

005

005

006

005

005

006