1

Checking the Global Settings of the CV-X Series

On the "Global" menu, select [Communications & I/O] > [PLC-Link].

2

Select "OK" to close the "PLC-Link" setting screen and then restart the
controller.

Configure the PLC‐Link settings.

Mode: PLC- Link (RS- 232C)
PLC Type: MELSEC FX Series
Baud Rate: 19200
Stop Bit: 1
Parity Bit: Even
Flow Control: CTS/RTS
Data Length: 8- bit (fixed)
* The above is a setting example. Change the
settings according to the target device.

Decimal Point: Fixed- point

Command Execute Event: Polling
Command Complete Address (bit): 00003
Command Address: 00100
Command Result Address: 00200
Result Output Address: 00500
Result Ready Address (bit): 00000
Result Ack Address (bit): 00001
Acknowledge result output completion:
Checked
Enable Handshake: Unchecked

[Note]

The memory range that can be used

varies according to the target device.
Furthermore, frequently accessing a memory
with EEPROM (non-volatile memory)
assigned may lead to delays, and a shorter
device lifespan.

Ensure that you have thoroughly checked
the memory range of the device to be
connected before using it.

1. Establishing the PLC-Link

(RS-232C PLC-Link) [MELSEC FX Series]

This section describes how to establish the PLC‐Link.

[Important] If it fails, follow this manual to configure the settings and check the operations.

Confirm that it operates properly, and change settings if necessary.