Checking the Global Settings of the CV-X Series
On the "Global" menu, select [Communications & I/O] > [PLC-Link].
2
Select "OK" to close the "PLC-Link" setting screen and then restart the
controller.
Configure the PLC‐Link settings.
Mode: PLC- Link (RS- 232C)
PLC Type: MELSEC FX Series
Baud Rate: 19200
Stop Bit: 1
Parity Bit: Even
Flow Control: CTS/RTS
Data Length: 8- bit (fixed)
* The above is a setting example. Change the
settings according to the target device.
Decimal Point: Fixed- point
Command Execute Event: Polling
Command Complete Address (bit): 00003
Command Address: 00100
Command Result Address: 00200
Result Output Address: 00500
Result Ready Address (bit): 00000
Result Ack Address (bit): 00001
Acknowledge result output completion:
Checked
Enable Handshake: Unchecked
[Note]
The memory range that can be used
varies according to the target device.
Furthermore, frequently accessing a memory
with EEPROM (non-volatile memory)
assigned may lead to delays, and a shorter
device lifespan.
Ensure that you have thoroughly checked
the memory range of the device to be
connected before using it.
1. Establishing the PLC-Link
(RS-232C PLC-Link) [MELSEC FX Series]
This section describes how to establish the PLC‐Link.
[Important] If it fails, follow this manual to configure the settings and check the operations.
Confirm that it operates properly, and change settings if necessary.