Indicator Specifications
■
Indicator specifications during setting change, checking, and while in operation
List of Optional Accessories
Indicator
Lighting specifications
Description
ION MONITOR
One of the "ION MONITOR" lights is illuminated
Charge level display
Displays the target's static charge. When the
leftmost (or rightmost) indicator is illuminated, it
means that the target's negative (or positive)
static charge is very high. The indicator
illuminated changes according to the quantity
of the target's static charge.
One of the "ION MONITOR" lights flashes.
Frequency setting
When the frequency is set, the indicator
corresponding to the set frequency will flashes
for approximately five seconds.
See “Frequency setting” (page 4).
The ION MONITOR indicator in the middle
flashes red.
Normal static elimination interruption
The indicator will flash red when static
elimination is interrupted by short-circuiting the
blue and pink wires of the 10-pin I/O cable.
ION/ALM/COND
The ION/ALM/COND flashes once per second
Condition warning
The indicator flashes if the ion balance is bad
due to the influence of the installation
environment.
Flashes Green
:Sensitivity low
When the alarm level is changed to another
level, the indicator will flash slowly for approx.
five seconds.
When the condition warning and the ion level
warning occur at the same time, the "ION/ALM/
COND" indicator flashes first for the ion level
warning.
The ION/ALM/COND indicator flashes twice per
second.
Ion level warning
The indicator flashes when the quantity of ion
generation drops below the set value.
Flashes Green
:Sensitivity low
When the alarm level is changed to another
level, the indicator will flash slowly for approx.
five seconds.
When the condition warning and the ion level
warning occur at the same time, the "ION/ALM/
COND" indicator flashes first for the ion level
warning.
ION/ALM/COND, ION
MONITOR
The ION/ALM/COND indicator and the all ION
MONITOR indicator flash red.
Alarm
When an abnormal electric discharge occurs or
the internal circuit is damaged, the ION/ALM/
COND indicator will flash three times per
second and the ION MONITOR indicators will
flash red slowly.
Item
Type
Appearance
Description
10-pin I/O cable
SJ-C2U (2m)
SJ-C5U (5m)
SJ-C10U (10m)
Power cable for the SJ-HA Series.
Three types (2-, 5-, 10-m cables)
are available.
(Cable color: Gray)
10 pin-10 pin cable
OP-42210 (2m)
OP-42211 (5m)
OP-42212 (10m)
Cable for connecting the SJ-HA
Series units. Three types (2-, 5-, 10-
m cables) are available. Use this
cable to connect to the coupled
Relay Box.
(Cable color: Gray)
10-to-10-pin cable for SJ-H036A
SJ-C2H (2m)
SJ-C5H (5m)
SJ-C10H (10m)
The cable that connects the
SJ-H036A controller to the bar.
Three types (2-, 5-, 10-m cables)
are available.
(Cable color: Black)
Tungsten electrode probes
(four) for SJ-HA
OP-84293
Tungsten-made electrode probes
(Made for SJ-HA)
Connection relay box
OP-84296
Used for connecting SJ-HA units
together.
End unit
OP-84301
Used for installing the SJ-HA Series.
Auxiliary support component
OP-84300
Used to for installing
SJ-HA Series.
Electrode probe cleaning kit
OP-84299
Used for maintaining the electrode
probes on the SJ-HA Series.
Replacement filters for the
electrode cleaning kit
(10 pieces)
OP-42218
Cotton filters for the cleaning kit.
Electrode probe cleaning kit 2
OP-84454
Used to perform maintenance on
the inside wall of the electrode
probe cap.
Replacement filter for the
electrode probe cleaning kit 2
(10 pieces)
OP-84455
Replacement filters for the cleaning
kit 2.
SJ-GL/G/V/R exchange
side supports
OP-84297
Used to match the installation
dimensions of the SJ-GL/G/V/R
Series. Also used for rotation.
SJ-GL/G/V/R exchange
central supports
OP-84298
Used to match the installation
dimensions of the SJ-GL/G/V/R
Series. Also used for rotation.
Electrode probe replacement kit OP-84363
Used for changing the electrode
probes on the SJ-HA Series.