Indicator Specifications

„

Indicator specifications during setting change, checking, and while in operation

List of Optional Accessories

Indicator

Lighting specifications

Description

ION MONITOR

One of the "ION MONITOR" lights is illuminated

Charge level display
Displays the target's static charge. When the
leftmost (or rightmost) indicator is illuminated, it
means that the target's negative (or positive)
static charge is very high. The indicator
illuminated changes according to the quantity
of the target's static charge.

See "Indicators" (page 5).

The rightmost two ION MONITOR indicators are
illuminated red.

Continuous positive ion generation
Positive ions are generated continuously

The leftmost two ION MONITOR indicators are
illuminated red.

Continuous negative ion generation
Negative ions are generated continuously

A single ION MONITOR indicator on the
positive side is illuminated along with a single
ION MONITOR on the negative side.

Ion quantity indicator
Displays the quantity of ions generated by the
SJ-H/SJ-HV/SJ-HC Series.

See "Indicators" (page 5).

One of the "ION MONITOR" lights flashes.

Frequency setting
When the frequency is set, the indicator
corresponding to the set frequency will flashes
for approximately five seconds.

See "Frequency Settings" (page 4).

The ION MONITOR indicator in the middle
flashes red.

Normal static elimination interruption
The indicator will flash red when static
elimination is interrupted by short-circuiting the
blue and pink wires of the 10-pin I/O cable.

The ION MONITOR indicators on the left and
right flash red.

Forced static elimination interruption
The indicator will flash red when static
elimination is interrupted by the remote control,
regardless of the static elimination setting of the
10-pin I/O cable.

The ION MONITOR indicators on the left and
right flash green.

Forced static elimination
The indicator will flash green when static
elimination is started by the remote control,
regardless of the static elimination setting of the
10-pin I/O cable.

ION/ALM/COND

The ION/ALM/COND flashes once per second

Condition warning
The indicator flashes if the ion balance is bad
due to the influence of the installation
environment.
Flashes Green

:Sensitivity low

Flashes Yellow

:Sensitivity medium

Flashes Red

:Sensitivity high

OFF

:No sensitivity setting

When the alarm level is changed to another
level, the corresponding color will flash slowly
for approximately five seconds.
When the condition warning and the ion level
warning occur at the same time, the "ION/ALM/
COND" indicator flashes first for the ion level
warning.

The ION/ALM/COND indicator flashes twice per
second.

Ion level warning
The indicator flashes when the quantity of ion
generation drops below the set value.
Flashes Green

:Sensitivity low

Flashes Yellow

:Sensitivity medium

Flashes Red

:Sensitivity high

OFF

:No sensitivity setting

When the alarm level is changed to another
level, the corresponding color will flash slowly
for approximately five seconds.
When the condition warning and the ion level
warning occur at the same time, the "ION/ALM/
COND" indicator flashes first for the ion level
warning.

ION/ALM/COND, ION
MONITOR

The ION/ALM/COND indicator and the all ION
MONITOR indicator flash red.

Alarm
When an abnormal electric discharge occurs or
the internal circuit is damaged, the ION/ALM/
COND indicator will flash three times per
second and the ION MONITOR indicators will
flash red slowly.

RC

The RC indicator illuminates or flashes

Remote control
The indicator is illuminated for flashes when the
SJ-H* Series is under remote control.
Illuminates Yellow

: Remote control is locked.

Flashes Yellow

:The ID number of the static

elimination bar from the
remote control is selected or
the remote control lock is
unlocked

Quickly Flashes Yellow

:The ID number is selected

during lock or the remote
control lock is set.

OFF

: Remote control is not locked.

The RC indicator flashes once per second

Dual I.C.C. setting/confirmation
The indicator flashes after Dual I.C.C. setting or
confirmation.
Flashes Green

: Dual I.C.C. ON

Flashes Red

: Dual I.C.C. OFF

The RC indicator flashes twice per second

Ion balance adjustment confirmation
The indicator flashes after confirmation of
whether the ion balance is being adjusted.
Flashes Green

: Ion balance adjustment OFF

Flashes Red

: Ion balance adjustment ON

The RC indicator flashes three times per
second

L.P.C. setting/confirmation
The indicator flashes after L.P.C. setting or
confirmation.
Flashes Green

: L.P.C. OFF

Flashes Red

: L.P.C. ON

Item

Type

Appearance

Description

10-pin I/O cable

SJ-C2U
SJ-C5U
SJ-C10U

Power cable for the SJ-H* Series.
Three types (2-, 5-, 10-m cables)
are available.
(Cable color: Gray)

10 pin-10 pin cable

OP-42210
OP-42211
OP-42212

Cable for connecting the SJ-H*
Series units. Three types (2-, 5-, 10-
m cables) are available. This cable
connects to the Relay Box as well.
(Cable color: Gray)

10-to-10-pin cable for SJ-H036

SJ-C2H
SJ-C5H
SJ-C10H

The cable that connects the
SJ-H036 controller to the bar. Three
types (2-, 5-, 10-m cables) are
available.
(Cable color: Black)

Tungsten electrode probes (four)
for SJ-H
Tungsten accelerating
electrode probes (two) for SJ-H

OP-84292

Tungsten-made electrode probes and
accelarating electrode probes (Made
for SJ-H)

Tungsten electrode probes
(four) for SJ-HA

OP-84293

Tungsten-made electrode probes
(Made for SJ-HA)

Tungsten electrode probes
(four) for SJ-HV

OP-84294

Tungsten-made electrode probes
(Made for SJ-HV)

Silicon electrode probes (four)
for SJ-HC

OP-84295

Silicon-made electrode probes
(Made for SJ-HC)

Relay Box for SJ-H* Series

OP-84296

Used for connecting SJ-H* units
together.

End unit for SJ-H* Series

OP-84301

Used for installing the SJ-H* Series.

Auxiliary support
for SJ-H* Series

OP-84300

Used to for installing
SJ-H* Series.

Electrode probe cleaning kit
for SJ-H* Series

OP-84299

Used for maintaining the electrode
probes on the SJ-H* Series.
* This cannot be used when the

laminar flow assisting part is a
attached.

Replacement filters for the
electrode cleaning kit
(10 pieces)

OP-42218

Cotton filters for the cleaning kit.

Electrode probe cleaning kit 2
for the SJ-H* Series

OP-84454

Used to perform maintenance on
the inside wall of the electrode
probe cap.

Replacement filter for the
electrode probe cleaning kit 2
(10 pieces)

OP-84455

Replacement filters for the cleaning
kit 2.

SJ-GL/G/V/R exchange
side supports

OP-84297

Used to match the installation
dimensions of the SJ-GL/G/V/R
Series. Also used for rotation.

SJ-GL/G/V/R exchange
central supports

OP-84298

Used to match the installation
dimensions of the SJ-GL/G/V/R
Series. Also used for rotation.

Electrode probe replacement kit
for SJ-H* Series

OP-84363

Used for changing the electrode
probes on the SJ-H* Series.

Straight air booster starter unit

SJ-HS01

Used to increase the static
elimination speed.

Wide angle booster starter unit

SJ-HW01

Used to widen the static elimination
range.

Extension unit for straight air
booster

SJ-HS02

Used to extend the auxiliary air
straight unit.

Extension unit for wide angle
booster

SJ-HW02

Used to extend the auxiliary air
diffusion unit.

Sealing extension unit for air
booster

SJ-HM01

Used over areas where auxiliary air
should not be used.

End unit for air booster

OP-84386

Used to mount the SJ-H* Series
wearing an air booster.

Auxiliary support for air booster

OP-84385

Used to mount the SJ-H* Series
wearing an air booster.

Laminar flow assisting part
starter unit

OP-84380

Supports the laminar downflow.

Extension unit for laminar flow
assisting part

OP-84381

Used to extend the laminar flow
assisting part.

Electrode probe replacement kit
for laminar flow assisting part

OP-84382

Used to replace the electrode
probes when the laminar flow
assisting part is attached.

Remote Control Console
for SJ-H* Series

SJ-H01

Remote Control Console to operate
the SJ-H* Series