Relationships between installation speed and static elimination speed due to frequency settings.

This displays the relationship between frequency settings and static elimination speed and installation distance
zSJ-H Series

zSJ-HA Series

zSJ-HV Series

zSJ-HC Series

0

5

10

15

20

25

30

0

200

400

600

800 1000 1200 1400 1600

Operating distance[mm]

Static elimination time[sec]

10Hz
5Hz
3Hz
1Hz

Measurement conditions:
The time required to eliminate the static charge of
the target from

±1000 V to ± 100 V is measured.

The 150 x 150mm plate monitor (20 pF) is used.
SJ-H108 is used.
No downflow.

Measurement conditions:
The time required to eliminate the static charge of
the target from

±1000 V to ± 100 V is measured.

The 150 x 150mm plate monitor (20 pF) is used.
SJ-H108 is used.
Under the downward air flow of 0.3 m/sec.

0

5

10

15

20

25

0

50

100

150

200

250

300

Static elimination time[sec]

Operating distance[mm]

33Hz

22Hz

0

5

10

15

20

25

30

0

200

400

600

800 1000 1200 1400 1600

Operating distance[mm]

Static elimination time[sec]

10Hz
5Hz
3Hz
1Hz

Measurement conditions:
The time required to eliminate the static charge of
the target from

±1000 V to ±100 V is measured. The

150 x 150mm plate monitor (20 pF) is used.
SJ-H108A is used.
No downflow

Measurement conditions:
The time required to eliminate the static charge of
the target from

±1000 V to ±100 V is measured. The

150 x 150mm plate monitor (20 pF) is used.
SJ-H108A is used.
Under the downward air flow of 0.3 m/sec.

0

5

10

15

20

25

0

50

100

150

200

250

300

Static elimination time[sec]

Operating distance[mm]

33Hz
22Hz

33Hz
22Hz

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

0

50

100

150

200

250

300

Operating distance[mm]

Static elimination time[sec]

Measurement conditions:
The time required to eliminate the static charge of
the target from

±1000 V to ±100 V is measured. The

150 x 150mm plate monitor (20 pF) is used.
SJ-H108V is used.
Air supply 16 /min, no downflow

Measurement conditions:
The time required to eliminate the static charge of
the target from

±1000 V to ± 100 V is measured.

The 150 x 150mm plate monitor (20 pF) is used.
SJ-H108V is used.
Air Supply 16 /min.
Under the downward air flow of 0.3 m/sec.

10Hz

5Hz

3Hz

1Hz

0

5

10

15

20

25

30

35

40

45

0

200

400

600

800 1000 1200 1400 1600

Operating distance[mm]

Static elimination time[sec]

33Hz
22Hz

0

5

10

15

20

25

30

0

50

100

150

200

250

300

Operating distance[mm]

Static elimination time[sec]

10Hz

5Hz

3Hz

1Hz

0

5

10

15

20

25

30

35

0

200

400

600

800 1000 1200 1400 1600

Operating distance[mm]

Static elimination time[sec]

Measurement conditions:
The time required to eliminate the static charge of
the target from

±1000 V to ±100 V is measured. The

150 x 150mm plate monitor (20 pF) is used.
SJ-H108C is used.
No downflow

Measurement conditions:
The time required to eliminate the static charge of
the target from

±1000 V to ±100 V is measured. The

150 x 150mm plate monitor (20 pF) is used.
SJ-H108C is used.
Under the downward air flow of 0.3 m/sec.