beautypg.com

KEYENCE SJ-H Series User Manual

Page 2

background image

2

Precautions for CSA Certificate

The SJ-H* Series complies with the following CSA and UL standards, and has been certified by CSA.

CAN/CSA-C22.2 No.61010-1
Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use

UL61010-1
Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use


• When selecting a power supply for use with the SJ-H* Series, always use a CSA/UL-listed power

supply that either provides Class 2 output as defined in the Canadian Electrical Code/National
Electrical Code, or that has been evaluated as a Limited Power Source as defined in CAN/
CSA-C22.2 No. 60950-1/UL60950-1.

• Always establish a proper ground connections when installing the SJ-H* Series.
• Use only the cables provided by KEYENCE (power cables and connector cables) to connect SJ-H*

Series units to one another or to their power supplies.

• Install the SJ-H* Series in accordance with the installation and wiring instructions described in this

instruction manual. Never operate the SJ-H* Series with the ratings that does not conform to the
specifications described in this instruction manual.
* Seven units can be connected only when the 36 V power supply is used.

Please contact the nearest KEYENCE office when the 24 V power supply is used.

Precautions for CE Marking

The SJ-H* Series complies with the following EU Directives and EN standards.

EU Directives
• EMC Directives (2004/108/EC)
• Low-voltage Directive (2006/95/EC)

EN Standards
• EN61326-1 Class A
• EN61010-1


• Be sure to completely ground the SJ-H* Series' ground terminal when installing the SJ-H* Series.
• Overvoltage Category (Installation Category): I
• Pollution Degree: 2
• When selecting a power supply for use with the SJ-H* Series, always use a power supply that has

been certified by a EU Notified Body (as a Limited Power Source as defined in EN60950).

• Use only the cables provided by KEYENCE (power cables and connector cables) to connect SJ-H*

Series units to one another or to their power supplies.

• Install the SJ-H* Series in accordance with the installation and wiring instructions described in this

instruction manual.Never operate the SJ-H* Series with the ratings that does not conform to the
specifications described in this instruction manual.
* Seven units can be connected only when the 36 V power supply is used.

Please contact the nearest KEYENCE office when the 24 V power supply is used.

Checking the Package Contents

The package of SJ-H* Series includes the following items. Ensure that these items are included in
your package before using the Unit. Extension cables and electrode probes for replacement are
available as options.

See "List of Optional Accessories" (page 9).

*1 Use these language warning labels and ID number seals as needed.

The cables are sold separately.

See "Cables" (page 3).

Part Names

This section lists the part names of the SJ-H* Series. For details about the operation keys and indicators
on the controller's front panel, see "Names and functions of operation keys, switches, and indicators".

1. Setting block (Not provided on SJ-H036*) (The ID switch is not provided on the SJ-HA Series)
2. Remote control infrared receiver (Not provided on the SJ-HA Series or SJ-H036*)
3. Indicator block (Not provided on SJ-H036*)
4. Cable connector (two on the SJ-H/HV/HC Series (except for SJ-H036*), and one on the SJ-HA

Series and SJ-H036*)

5. Terminator switch (Not provided on the SJ-HA Series or SJ-H036*)
6. Electrode probe
7. Accelerating electrode probe (Not provided on the SJ-HA/HV/HC Series)
8. Air supply opening (Two on SJ-H036*/060*/084*/108*/132*/156*/180*/204*, and three on

SJ-H228*/252*/300*)

1. Setting block (The ID switch is not provided on the SJ-H036A)
2. Remote control infrared receiver (Not provided on the SJ-H036A)
3. Indicator block
4. I/O Cable connector (Only one on the SJ-H036A)
5. Cable connector
6. Terminator switch (Not provided on the SJ-H036A)

Installation and Connection

This section explains how to set up and install the SJ-H* Series.
Before installation, carefully consider the operating conditions such as the distance between the static
elimination bar and the target, or the time required for the elimination of the target's static charge.

„

Static elimination speed and operating distance

The SJ-H* Series offers a variety of frequency settings to enable flexible static elimination
according to the location and application.

See "Frequency setting" (page 4).

„

Installation location

Refer to the following illustration to install the SJ-H* Series.

• Provide enough space between the static elimination bar and surrounding walls as shown

in the figures below.

• When mounting the SJ-H* Series, use the provided end unit and auxiliary support part,

otherwise an accident or malfunction may result.

• Be sure that the cable stays more than 10 mm away from the SJ-H* Series, otherwise an

accident or malfunction may result.

Contents

Auxiliary Support Part

SJ-H036* : 0
SJ-H060* : 0
SJ-H084* : 0
SJ-H108* : 0
SJ-H132* : 1
SJ-H156* : 1
SJ-H180* : 1
SJ-H204* : 1
SJ-H228* : 2
SJ-H252* : 2
SJ-H300* : 2

Ultra High-speed Sheath Sensing Ionizer

Instruction Manual

SJ-H(A)(V)(C) Series

SJ-H036*/060*/084*/108*/132*/156*/180*/204*/228*/252*/300*

0

1

2

3

4

5

6

7

8

9 10 11

12 13 14 15

SJ-H060*/084*/108*/132*/156*/180*/204*/228*/252*/300* Controller-built-in Static Eliminator

SJ-H036* Static Elimination Bar

SJ-H036* Controller

Electrode probe
replacement kit

End Units (L/R)

End Unit Securing Screws: 2

Instruction Manual

Flat-blade screwdriver

The CAUTION/WARNING labels in
Japanese, German, French, Italian,
and Chinese

*1

ID number seal

*1

NOTE

Static elimination bar (Control panel)

Control panel (SJ-H036*)

Static elimination ability

Static elmination speed

Location

Operating distance (mm)

Recommended frequency (Hz)

Production lines of films or sheets
(Short distance)

50-300

68, 47, 33, 22

Clean bench (Middle distance)

300-1000

10, 8, 5

On ceiling of clean room (Long distance)

1000-2000

3, 1

Precautions for installation

* The figure is for the SJ-H084*/108*/132*/156*/180*/204*/228*/252*/300*.

The position of Ion monitor of SJ-H060* is different from other models.
The position of it is located to the right side of Remote control infrared receiver.
SJ-H036* does not have 1 through 3 and 5.

8

3

5

1

4

7

6

2

3

1

2

5

4

6

High-speed

Low-speed

Caution

10 mm
min.

10 mm
min.

10 mm
min.

20 mm min.

10 mm
min.

10 mm
min.

10 mm min.