7

Settings when Remote Control Console is Used

This section explains setting items when the optional Remote Control Console is used.
* The SJ-HA Series does not have the remote control function.

It is necessary to set the FREQ switch of the SJ-H/SJ-HV/SJ-HC Series to 9 before using the SJ-H01
Remote Control Console (SJ-H01) to control the SJ-H/SJ-HV/SJ-HC Series.
For details, see the Instruction Manual of the SJ-H01 Remote Control Console.

If the SJ-H01 Remote Control Console is used to
control more than one SJ-H/SJ-HV/SJ-HC units, it is
convenient to set a unique ID number for each unit
individually.
The ID number can be set in hexadecimal between
0 and F (i.e., 16 in total). Turn the ID Switch with the
provided flat-blade screwdriver to set the ID number.

By using the SJ-H01 Remote Control Console the Dual I.C.C. (Ion Current Control) function can be
turned OFF. When the Dual I.C.C. function is turned OFF, it will be possible to use the ion balance
adjustment function to generate positive and negative ions at a fixed ratio.
For details, see the Instruction Manual of the SJ-H01 Remote Control Console.

It is possible to fine-tune the zero point of ion balance by using the SJ-H01 Remote Control Console.
This adjustment cannot be made by the static elimination bar by itself.
The zero point of the ion balance is adjusted before shipping. The zero point may shift according to
the environment of installation. The ion balance adjustment made by the SJ-H01 makes it possible to
maintain proper static elimination.
For details, see the Instruction Manual of the SJ-H01 Remote Control Console.

The L.P.C. (Long-cycle Pulse Control) function can be turned on when using the SJ-H01 Remote Con-
trol Console.

See "Other Functions" (page 5) for more information on the L.P.C. function.

Alarm states can be cleared when using the SJ-H01 Remote Control Console.
For details, see the Instruction Manual of the SJ-H01 Remote Control Console.

Any type of warning (Ion level warning, Condition warning or alarm) can be raised at any time when
using the SJ-H01 Remote Control Console.
For details, see the Instruction Manual of the SJ-H01 Remote Control Console.

The quantity of generated ions can be checked faster than usual using the SJ-H01 Remote Control Console.
For details, see the Instruction Manual of the SJ-H01 Remote Control Console.

Maintenance of Electrode Probes

When the SJ-H* Series is used for a long period, the electrode probes become dirty due to the accu-
mulation of dust.
If you continue to use the SJ-H* Series with dust accumulating on the electrode probes, the static
elimination ability may deteriorate, resulting in an accident or product breakdown. Therefore, be sure
to clean the electrode probes periodically.

Use an OP-84299 electrode probe cleaning kit for the SJ-H* Series or a cotton swab when performing
maintenance on the electrical probes.

• Turn off the SJ-H* Series before the maintenance of the electrode probes.

• Do not touch the electrode probes directly with your hand or fingers, as this may cause

injury. Be extremely careful when cleaning them.

„

Cleaning the electrode probes : OP-84299 Electrode probe cleaning kit for

the SJ-H* Series

Soak the filter of the cleaning kit with alcohol, and place the cleaning kit on the electrode probe and
rotate it gently two or three times.
The filter on the cleaning kit will remove any dirt from the electrode probes. Replacement filters
(OP-42218) are also available.

* For the information on how to remove the filter, refer to the Instruction Manual of the Electrode

Probe Cleaning Kit for the SJ-H Series.

„

Clean the electrode probe : Cotton bud

Clean the electrode probe with a cotton bud moistened with alcohol.

„

Changing the electrode probes

Place an OP-84363 electrode probe replacement kit over the electrode probe and press it towards
the device while rotating it counter-clockwise to remove the electrode probe.

To attach an electrode probe, place the new probe in the electrode probe replacement kit, line it up
with the grooves and insert it. Press the kit towards the device and turn clockwise to secure the elec-
trode probe.

• When attaching an electrode probe, line up the markings on the device and the markings on the electrode

probe.

• When attaching an electrode probe, check that the O-ring is at the designated position.

„

Changing the accelerating electrode probes

Place an OP-84363 electrode probe replacement kit over the accelerating electrode probe and press
it towards the device while rotating it counter-clockwise to remove the accelerating electrode probe.

To attach an accelerating electrode probe, place the new electrode probe in the replacement kit, line
it up with the grooves and insert it. Press the kit towards the device and turn clockwise to secure the
electrode probe.

When attaching the accelerating electrode probe, be sure to align the attachment marks on the SJ-H*

Series and the protrusions of the accelerating electrode probe.

The accelerating electrode probe can not be attached to the SJ-HA/SJ-HV/SJ-HC Series.

Frequency setting

ID number setting

Dual I.C.C. (Ion Current Control) setting

Ion balance adjustment function

L.P.C. function

Clearing an alarm state

Alarm output control function

Quick ion check function

Maintenance of electrode probes

SJ-H

Series

SJ-HA

Series

SJ-HV

Series

SJ-HC

Series

SJ-H

Series

SJ-HA

Series

SJ-HV

Series

SJ-HC

Series

SJ-H* Series ID number switch

0-9

A

B

C

D

E

F

Remote control ID number key
and ID number seal

0-9

10

11

12

13

14

15

SJ-H

Series

SJ-HA

Series

SJ-HV

Series

SJ-HC

Series

SJ-H

Series

SJ-HA

Series

SJ-HV

Series

SJ-HC

Series

SJ-H

Series

SJ-HA

Series

SJ-HV

Series

SJ-HC

Series

SJ-H

Series

SJ-HA

Series

SJ-HV

Series

SJ-HC

Series

SJ-H

Series

SJ-HA

Series

SJ-HV

Series

SJ-HC

Series

SJ-H

Series

SJ-HA

Series

SJ-HV

Series

SJ-HC

Series

Warning

NOTE

Device markings

Electrode probe markings

O-ring

NOTE

Attachment mark

Attachment mark