beautypg.com

Common specifications, Sl-vhs-im-e – KEYENCE SL-VHS Series User Manual

Page 8

background image

8

SL-VHS-IM-E

Response time (OSSD)

Units: ms

*1 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) is to be 80 ms or

more to ensure that the OSSD keeps OFF state for more than 80 ms.

When connecting the SL-VHS units in series, the response time (ON to OFF) is the sum of the response
times of all the individual SL-VHS units.

When connecting the SL-V32HS (32 beam axes), SL-V24HS (24 beam axes), and SL-V12HS (12
beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6 ms respectively, and
the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
the response time (OFF to ON) is 27.1 ms + 40 ms = 67.1 ms.

1.6 m/s is the maximum speed of movement of the test piece to which the detection capability is maintained.

Current consumption

Unit:mA

*1 When the SL-VHS is used under ambient temperatures between 45 to 55 °C, the Maximum load current should not

exceed 300 mA.

*2 Applies to situations when power is either off or disconnected.
*3 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cable)

must be 2.5 ohms or less to ensure operation. If the cable length is 15 m or more and the load’s current consumption is
200 mA or more, the wire resistance must be 1 ohm or less.

*4 When operating in ambient temperatures ranging from 45 to 55 °C, use incandescent lamps (24 VDC, 1 to 3 W) or LED

lamps (load current:10 to 100 mA).

*5 With IP-67conformity, the product is evaluated and proved by KEYENCE.

Model

Response time (OSSD)

ON to OFF

OFF to ON

*1

SL-V08HS

7

47

SL-V12HS

7.6

47.6

SL-V16HS

8.1

48.1

SL-V20HS

8.7

48.7

SL-V24HS

9.2

49.2

SL-V28HS

9.8

49.8

SL-V32HS

10.3

50.3

SL-V36HS

10.9

50.9

SL-V40HS

11.4

51.4

SL-V44HS

12

52

SL-V48HS

12.5

52.5

SL-V52HS

13.1

53.1

SL-V56HS

13.6

53.6

SL-V60HS

14.2

54.2

SL-V64HS

14.7

54.7

SL-V72HS

15.8

55.8

SL-V80HS

16.9

56.9

SL-V88HS

18

58

SL-V96HS

19.1

59.1

SL-V104HS

20.2

60.2

SL-V112HS

21.3

61.3

SL-V120HS

22.4

62.4

Model

When the center indicator is ON

When the center indicator is OFF

Transmitter

Receiver

Transmitter

Receiver

SL-V08HS

56

70

52

65

SL-V12HS

63

72

58

66

SL-V16HS

69

74

64

67

SL-V20HS

75

75

70

68

SL-V24HS

81

77

76

69

SL-V28HS

87

79

81

69

SL-V32HS

93

80

86

70

SL-V36HS

98

82

91

71

SL-V40HS

103

84

96

72

SL-V44HS

108

85

100

73

SL-V48HS

113

87

104

74

SL-V52HS

117

88

109

74

SL-V56HS

122

90

112

75

SL-V60HS

126

91

116

76

SL-V64HS

130

93

120

77

SL-V72HS

137

96

126

78

SL-V80HS

144

98

132

80

SL-V88HS

149

101

136

81

SL-V96HS

154

104

140

83

SL-V104HS

159

107

143

84

SL-V112HS

162

109

146

86

SL-V120HS

165

112

147

87

Reference

NOTE

Common specifications

Model

SL-VHS

Beam axis spacing/Lens diameter

20 mm/

φ5 mm

Detection capability

φ25 mm

Operating distance

0.1 m to 9.0 m (detection height of 1,260 mm or less)

0.1 m to 7.0 m (detection height of 1,400 mm or more)

Effective aperture angle

Max. ±2.5 ° (When operating distance is 3 m (9.84 ft.) or more)

Light source

Infrared LED (850 nm)

Operation form

Turns on when no interruptions are present in the detection zone

Rating

Power voltage

24 VDC +10 %, -20 % (Ripple P-P 10 % or less), Class 2

OSSD

Output

2 outputs each for PNP and NPN.

Can be changed by using the connector cable

Max. load current

500 mA

*1

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 7 m (22.97 ft.))

OFF state voltage

Max. 2.0 V (with a cable length of 7 m (22.97 ft.))

Leakage current

Max. 100 µA

*2

Max. capacitive load

1 µF (with a load resistance of 100

Ω)

Load wiring resistance

Max. 2.5

Ω

*3

Non safety-
related output

AUX

Output with automatic PNP/NPN switching function, 50 mA

max.

Alert output

Clear/Blocked Output

State information output 1, 2

Muting lamp output

Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp

(load current :10 to 300 mA)

*4

can be connected

Input

EDM input

Short-circuit current 10 mA

Wait input

Short-circuit current 2.5 mA

Reset input

Muting input 1, 2

Override input

Protection circuit

Reverse current protection, short-circuit protection for each

output, surge protection for each output

Environmental
condition

Enclosure protection

IP65, IP67

*5

Overvoltage Category

II

Operating ambient temperature

-10 to +55 °C (No freezing)

Storage ambient temperature

-25 to +60 °C (No freezing)

Operating relative humidity

15 % to 85 %RH (No condensation)

Storage relative humidity

15 % to 95 %RH

Surrounding light

Incandescent lamp: 5,000 lx or less. Sunlight: 20,000 lx or less

Vibration

10 to 55 Hz, 0.7 mm compound amplitude,

20 sweeps each in X, Y, and Z directions

Shock

100 m/s

2

(Approx. 10 G) 16 ms pulse,

in X, Y, Z directions 1,000 times each axis

Material

Main unit case

Aluminum

Upper case/Lower case

Zinc die-cast

Front cover

Polycarbonate, SUS304

Approved
standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 Class A

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)

IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)

IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL3)

EN ISO13849-1:2008 (Category 4, PL e)

UL508, UL1998