Common specifications, Sl-vhs-im-e – KEYENCE SL-VHS Series User Manual
Page 8

8
SL-VHS-IM-E
■
Response time (OSSD)
Units: ms
*1 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) is to be 80 ms or
more to ensure that the OSSD keeps OFF state for more than 80 ms.
When connecting the SL-VHS units in series, the response time (ON to OFF) is the sum of the response
times of all the individual SL-VHS units.
When connecting the SL-V32HS (32 beam axes), SL-V24HS (24 beam axes), and SL-V12HS (12
beam axes) in series, the response time of each unit is 10.3 ms, 9.2 ms, and 7.6 ms respectively, and
the response time (ON to OFF) is 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms.
the response time (OFF to ON) is 27.1 ms + 40 ms = 67.1 ms.
1.6 m/s is the maximum speed of movement of the test piece to which the detection capability is maintained.
■
Current consumption
Unit:mA
*1 When the SL-VHS is used under ambient temperatures between 45 to 55 °C, the Maximum load current should not
exceed 300 mA.
*2 Applies to situations when power is either off or disconnected.
*3 The wiring resistance between the OSSD output and the connected equipment (excluding the resistance of the cable)
must be 2.5 ohms or less to ensure operation. If the cable length is 15 m or more and the load’s current consumption is
200 mA or more, the wire resistance must be 1 ohm or less.
*4 When operating in ambient temperatures ranging from 45 to 55 °C, use incandescent lamps (24 VDC, 1 to 3 W) or LED
lamps (load current:10 to 100 mA).
*5 With IP-67conformity, the product is evaluated and proved by KEYENCE.
Model
Response time (OSSD)
ON to OFF
OFF to ON
*1
SL-V08HS
7
47
SL-V12HS
7.6
47.6
SL-V16HS
8.1
48.1
SL-V20HS
8.7
48.7
SL-V24HS
9.2
49.2
SL-V28HS
9.8
49.8
SL-V32HS
10.3
50.3
SL-V36HS
10.9
50.9
SL-V40HS
11.4
51.4
SL-V44HS
12
52
SL-V48HS
12.5
52.5
SL-V52HS
13.1
53.1
SL-V56HS
13.6
53.6
SL-V60HS
14.2
54.2
SL-V64HS
14.7
54.7
SL-V72HS
15.8
55.8
SL-V80HS
16.9
56.9
SL-V88HS
18
58
SL-V96HS
19.1
59.1
SL-V104HS
20.2
60.2
SL-V112HS
21.3
61.3
SL-V120HS
22.4
62.4
Model
When the center indicator is ON
When the center indicator is OFF
Transmitter
Receiver
Transmitter
Receiver
SL-V08HS
56
70
52
65
SL-V12HS
63
72
58
66
SL-V16HS
69
74
64
67
SL-V20HS
75
75
70
68
SL-V24HS
81
77
76
69
SL-V28HS
87
79
81
69
SL-V32HS
93
80
86
70
SL-V36HS
98
82
91
71
SL-V40HS
103
84
96
72
SL-V44HS
108
85
100
73
SL-V48HS
113
87
104
74
SL-V52HS
117
88
109
74
SL-V56HS
122
90
112
75
SL-V60HS
126
91
116
76
SL-V64HS
130
93
120
77
SL-V72HS
137
96
126
78
SL-V80HS
144
98
132
80
SL-V88HS
149
101
136
81
SL-V96HS
154
104
140
83
SL-V104HS
159
107
143
84
SL-V112HS
162
109
146
86
SL-V120HS
165
112
147
87
Reference
NOTE
Common specifications
Model
SL-VHS
Beam axis spacing/Lens diameter
20 mm/
φ5 mm
Detection capability
φ25 mm
Operating distance
0.1 m to 9.0 m (detection height of 1,260 mm or less)
0.1 m to 7.0 m (detection height of 1,400 mm or more)
Effective aperture angle
Max. ±2.5 ° (When operating distance is 3 m (9.84 ft.) or more)
Light source
Infrared LED (850 nm)
Operation form
Turns on when no interruptions are present in the detection zone
Rating
Power voltage
24 VDC +10 %, -20 % (Ripple P-P 10 % or less), Class 2
OSSD
Output
2 outputs each for PNP and NPN.
Can be changed by using the connector cable
Max. load current
500 mA
*1
Residual voltage (during ON)
Max. 2.5 V (with a cable length of 7 m (22.97 ft.))
OFF state voltage
Max. 2.0 V (with a cable length of 7 m (22.97 ft.))
Leakage current
Max. 100 µA
*2
Max. capacitive load
1 µF (with a load resistance of 100
Ω)
Load wiring resistance
Max. 2.5
Ω
*3
Non safety-
related output
AUX
Output with automatic PNP/NPN switching function, 50 mA
max.
Alert output
Clear/Blocked Output
State information output 1, 2
Muting lamp output
Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp
(load current :10 to 300 mA)
*4
can be connected
Input
EDM input
Short-circuit current 10 mA
Wait input
Short-circuit current 2.5 mA
Reset input
Muting input 1, 2
Override input
Protection circuit
Reverse current protection, short-circuit protection for each
output, surge protection for each output
Environmental
condition
Enclosure protection
IP65, IP67
*5
Overvoltage Category
II
Operating ambient temperature
-10 to +55 °C (No freezing)
Storage ambient temperature
-25 to +60 °C (No freezing)
Operating relative humidity
15 % to 85 %RH (No condensation)
Storage relative humidity
15 % to 95 %RH
Surrounding light
Incandescent lamp: 5,000 lx or less. Sunlight: 20,000 lx or less
Vibration
10 to 55 Hz, 0.7 mm compound amplitude,
20 sweeps each in X, Y, and Z directions
Shock
100 m/s
2
(Approx. 10 G) 16 ms pulse,
in X, Y, Z directions 1,000 times each axis
Material
Main unit case
Aluminum
Upper case/Lower case
Zinc die-cast
Front cover
Polycarbonate, SUS304
Approved
standards
EMC
EMS
IEC61496-1, EN61496-1, UL61496-1
EMI
EN55011 ClassA, FCC Part15B ClassA, ICES-003 Class A
Safety
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL3)
EN ISO13849-1:2008 (Category 4, PL e)
UL508, UL1998