Pausing the discharge, Jog function, Pausing the jog cycle – Hardy HI 3010 Filler/Dispenser Controller User Manual
Page 52: 30 discharging on, Discharging paused, 32 jog on display, 34 jog off display fig. 4

39
CHAPTER 4
Operating Procedures/Dispenser
FIG. 4-30 DISCHARGING ON
Step 4. When the discharge is complete, the instrument
closes the discharge gate and returns to the Dis-
pense On display or the Standby Display depending
on the dispensing cycle.
Pausing the Discharge
•
To pause the discharge, press the Stop but-
ton once. (See Fig. 4-31)
•
To resume discharging, press the Start but-
ton.
FIG. 4-31 DISCHARGING PAUSED
Jog Function
Step 1. If the loss-in-weight detected in the wait timer state
(See Fig. 4-25) is below the target window and the
Jog Function is turned ON, the Jog function auto-
matically comes on. (See Fig.4- 32)
FIG. 4-32 JOG ON DISPLAY
Step 2. The Filler/Dispenser goes through one JOG
sequence that was previously set up. (See Fig. 4-
33 & 4-34) To set up the JOG Parameters see the HI
3010 Installation and Service Manual.
FIG. 4-33 JOG OFF DISPLAY
Step 3. The instrument goes to the Jog Off state where it
checks to see if the loss in weight is within the tar-
get window. A timer is displayed counting down the
time the instrument is in the Jog Off state. If the
weight is within the target window the dispense
process continues going through the dispense
cycles until all cycles are complete.
FIG. 4-34 JOG DISPLAY/COMPLETED FOUR JOG
SEQUENCES/CHECKING WEIGHT
Pausing the Jog Cycle
•
You can pause the JOG cycle by pushing
the Stop button once at any time during the
JOG cycle. The JOG Hold display
appears. (See Fig. 4-35)
FIG. 4-35 JOG PAUSED 1.50 SECONDS INTO THE
JOG SEQUENCE
Step 4. If the loss in weight is still NOT within the target
window, the instrument automatically continues
through the preset JOG sequences until the target
window is reached and then continues to another
dispense cycle. (See Fig. 4-36)
NOTE:
To prevent Jogging make sure you turn the Auto
Pre-Act ON. It is important to note that if Auto
Preact is ON, the Filler/Dispenser will automati-
cally adjust the Ingredient Pre-Act parameter