Cub Cadet ZT-3400 User Manual
Page 49
ZT-2800
®
/ZT-3100/ZT-3400™
47
Integrated Zero-Turn Transaxle: The combination of a hydrostatic transmission and gear case
in one housing to form a complete transaxle.
Manifold: A conductor which provides multiple connection ports.
Neutral: Typically described as a condition in which fluid flow and system pressure is below that
which is required to turn the output shaft of the motor.
Pressure Decay: A falling pressure.
Priming: The filling of the charge circuit and closed loop of the fluid power system during start
up, frequently achieved by pressurizing the fluid in the inlet line.
Purging: The act of replacing air with fluid in a fluid power system by forcing fluid into all of the
components and allowing the air a path of escape.
Rated Flow: The maximum flow that the power supply system is capable of maintaining at a
specific operating pressure.
Scoring: Scratches in the direction of motion of mechanical parts caused by abrasive contami-
nants.
Swash Plate: A mechanical device used to control the displacement of the pump pistons in a
fluid power system.
System Charge Check Valve: A valve controlling the replenishing flow of fluid from a charge
circuit to the closed loop in a fluid power system.
System Pressure: The pressure which overcomes the total resistance in a system, including all
efficiency losses.
Valve: A device which controls fluid flow direction, pressure, or flow rate.
Variable Displacement Pump: A pump in which the displacement per revolution can be var-
ied.
Volumetric Displacement: The volume for one revolution.