CONTROL PANEL
Operation of the ThermElect system is automatic. All operational functions are stored in its microprocessor in
function locations and are factory preset. If necessary, the installer can adjust them through the control panel.
(See Figure 1.)
Four-Digit LED Display
The four digit LED displays specific operating information. During an editing
process, the function locations and the values set in these locations are displayed
for viewing and adjusting purposes.
AM and PM Indicator Lights
The AM and PM indicator lights are only utilized if the Steffes Time Clock Module
is being installed. With this module installed, the system displays time on AM/PM
intervals and the corresponding light flashes. The system can be configured to
display military time, in which case both the AM and PM lights illuminate.
Mode (Edit) Button
Activates the editing menu for changing the operating
information of the system.
Up and
Down Arrow Buttons
Used to scroll up or down when viewing or changing
operating functions.
Interface Port
FOR SERVICE USE ONLY! Allows technician external access for updating software and troubleshooting.
OPERATING STATUS
The ThermElect system is set to display various operating information as described below. Press and release the
up arrow to view this data.
Operating Mode - Indicates the current operating mode of the system.
C = Off-Peak (Charge) Time
P = On-Peak (Control) Time
A = Anticipated Peak Time
Outdoor Temperature -“O” followed by a number indicates current outdoor temperature.
Heat Call Status - Indicates the current heat call status being received from the room thermostat.
HC_0 = No Heat Call
HC_1 = Stage 1 Heat Call
HC_2 = Stage 2 Heat Call
HC_3 = Emergency Heat
COOL = Cooling/Air Conditioning Call
Brick Core Charge Level - “CL” (charge level) followed by a number indicates the current
percentage of heat stored in the brick core. “CL:_” represents zero percent and “CL: F” repre-
sents a full core charge level.
Targeted Brick Core Charge Level - “tL” (target level) followed by a number indicates the
current percentage of brick core charge being targeted by the system. A display of “tL:_” indi-
cates a target level of zero percent and “tL: F” indicates a full core charge target level.
Load Control - Current demand (kW) divided by 10. A value of "d 75" is equal to a current
demand of 750kW.
O
PERATION
1.02
T
HERM
E
LECT
A bar illuminates on the lower portion of
the display's second digit whenever one or
more heating elements are energized.
CAUTION
Editing operating
information may alter
the performance and
operation of the system.
CONTROL PANEL
FIGURE 1
STEFFES CORPORATION
M
M
M
P
P
M
M
A
A
Operation
Ч
Ш
M