Lugs ground, Comfort plus hydronic appendix, A.06 – Steffes 5140 Owner & Installers Manual User Manual
Page 31: Control circuit, Base io board, Neutral lug
line Voltage Wiring Diagram - Model 5130
240V Or 208V SYSTEMS ONlY
Use copper or aluminum conductors rated for 75
o
C or higher for field connection of this device.
NOTE 1: line Voltage Field Wiring Connections. See Figure 8 for information on proper circuit phasing.
NOTE 2: For more information regarding pump (circulator) wiring, reference Figures 9, 15 and 16 in the
Installation section of this manual.
Comfort Plus Hydronic
Appendix
A.06
BROWN
RED
BLUE
BLACK
NO
COM
HEATING ELEMENTS
Element 12
Element 11
Element 10
Element 9
Element 8
Element 5
Element 6
Element 7
Element 4
Element 3
Element 2
Element 1
COM
NO
COM
BLACK/YELLOW
NO
NO
COM
L2 240
RED
COM
NO
L2 120
COM
NO
COM
COM
COM
1/4 Amp
L1
NO
COM
COM
NO
NO
NO
ORANGE
BLACK
To Optional Static
Heat Recovery System
75VA
240v 24v
TRANSFORMER
WHITE/BLACK
CORE
LIMIT
LIMIT
CORE
L2 240
RED
L2 120
L1
NO
COM
BLACK/YELLOW
LIMIT
CORE
RED
COM
1/4 Amp
NO
COM
NO
NO
COM
NO
COM
NO
CONTROL CIRCUIT
Red & White To
Primary Loop Pump
(Max 1.2 AMPS)
Black & White
To Air Handler Pump
(Max 1.2 AMPS)
ORANGE
BLUE/BLACK
BLUE/WHITE
RED
BLACK
To Optional Air Handler
WHITE/BLACK
L2 240
RESISTER
DAMPER
BLOWER
RESISTOR
COM
NO
COM
NO
BASE IO BOARD
BLACK/YELLOW
5 Amp
BLUE
L2 120
1/4 Amp
NO
COM
NO
COM
4uf
EXCHANGER
LIMITS
WHITE
MANUAL
N.C.
225 °
RESET
AUTO
RESET
N.C.
250 °
COM.
Cap.
BLACK
CORE BLOWER
HIGH
CIRCUIT #3
CHARGE
CIRCUIT #4
CHARGE
CIRCUIT #1
CHARGE
CIRCUIT #2
CHARGE
CIRCUIT
BLOWERS/ CONTROLS
NEUTRAL LUG
SEE NOTE 1
SEE NOTE 2
ELEMENT 1
ELEMENT 2
ELEMENT 3
ELEMENT 4
ELEMENT 5
ELEMENT 6
ELEMENT 11
ELEMENT 12
ELEMENT 7
ELEMENT 8
ELEMENT 9
ELEMENT 10
Relays
1,5,9
To
Element
Relays
Relays
Relays
4,8,12
3,7,11
2,6,10
Element
To
Element
To
To
Element
EXPANSION
BOARD
#2
#1
EXPANSION
BOARD
LUGS
GROUND
PRIMARY
LOOP PUMP
SHRU
L1
WHITE
OR