Important, Configuration menu – Steffes 5140 Owner & Installers Manual User Manual
Page 23
confiGuration Menu
The Steffes Comfort Plus Hydronic heating system has a Configuration Menu,
which allows the system to be customized to the power company and consumer’s
needs. This menu can be accessed on start-up and allows configuration settings
to be easily adjusted.
To access the Configuration Menu:
Step 1 Energize the system. Access to the Configuration Menu is allowed
for the first two (2) minutes of operation. If the system has been
energized for more than two (2) minutes, the 15 amp circuit
breaker must be powered off and back on to gain access to this menu.
Step 2 Press and release the M button until the faceplate displays “CONF”.
Step 3 Press the up arrow once and the faceplate will display “C000”.
The faceplate will flash between “C000”
and the corresponding configuration value.
Step 4 If necessary, edit the configuration value by pressing and holding the M button while using the up or the
down arrow button to change the value.
Step 5 Once the value is correct, release the buttons and press the up arrow button to go to the next
configuration (C001,C002, etc.)
Step 6 Repeat steps 4 through 5 until all configuration settings have been adjusted to the desired values.
Step 7 Once configured, use the down arrow to leave the Configuration Menu.
In most applications only a few, if any, configuration changes will be necessary. Following is a description of the
configuration settings and their function:
C000
Off-Peak Method of Charge Control - Sets the method of brick core charging to be used during off-
peak (charge) periods. System is configured for automatic charge control which is a value of five (5).
C001
Start Brick Core Charge Set Point - If utilizing automatic charge control as set in C000, this value
indicates the outdoor temperature at which the system will start charging.
C002
Full Brick Core Charge Set Point - If utilizing automatic charge control as set in C000, this value
indicates the outdoor temperature at which the system will target a full core charge.
C003
Power line Carrier (PlC) Channel Selection - If using PLC communication, this setting must match
the channel setting in the Steffes PLC transmitting device. A value of zero indicates power line carrier
communication is disabled.
C004
Optional Controls Configuration
Value
Configuration Description
8 No Outdoor Sensor/No Time Clock Module
9 Outdoor Sensor/No Time Clock Module
12 No Outdoor Sensor/Time Clock Module (unlocks C013-C021)
13 Outdoor Sensor/Time Clock Module (unlocks C013-C021)
C005
Control Switch Configuration – If utilizing power line carrier control, the Steffes Time Clock Module,
line voltage peak control, or if the utility control switch opens for charging this value should be zero (0).
For all other applications, this value should be one (1).
Configuration Menu continued on next page...
If access to the Configuration
Menu times out, the 15 amp
circuit breaker must be
powered off and back on to
re-enter the menu.
IMPORTANT
Installation
3.13
Comfort Plus Hydronic
Comfort Plus Hydronic
Installation
3.14