Table 2, Notes – Panasonic WJ-SQ308 User Manual
Page 11
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
Table 2
Signal Output Condition
Without VCR
With VCR
Sequential switching Time
C-A: The sequential switcher's timing can
be adjusted using the Time Control (1)
when the Internat/External Selection
Switch (2) is set to the I NT position.
C-B/C:The signals are synchronized with C-A
when the Time Internal/External Selec
tion Switch (2) on WJ-SQ308S (C-B
and C-C) are set to the EXT position.
Set Internal/External (C-A) Selection
switch to I NT position.
All of the WJ-SQ308 is can be sequenced
with the timing pulse from VCR;
Note: Be sure to set the Time Inter
nal/External Selection Switch (2) to the
EXT position
Normal Sequence mode
1. Alarm/Spot Output Connec
tor
2. Atarm/Sequential Output
Connector
The signal from all of the WJ-SQ308s are
output sequentially with the switching time
from the C-A Unit.
All of the WJ-SQ308S are sequenced with the
timing pulse from the VCR.
Spot mode
1. Alarm/Spot Output Connec
tor
2. Atarm/Sequential Output
Connector
1. The WJ-SQ308 in the spot mode supplies
the selected video signal to the Alarm
Spot Output Connector (11). All Other WJ-
SQ308s go to sequencing with the timing
set by the WJ-SQ308 (C-A).
2. The signal from all of the WJ-SQ308S are
output sequentially with the switching time
set by the WJ-SQ308 (C-A).
1. The WJ-SQ308 In the spot mode supplies
the selected video signal to the Alarm
Spot Output Connector (11). All other WJ-
SQ308s go to sequencing with the switch
ing time set by the timing pulse from VCR.
2. The signal from all of the WJ-SQ308s are
switched with the switching time by the
timing pulse from VCR
Alarm mode (1 input)
1. Alarm/Spot Output Connec
tor
2. Alarm/Sequence Output
Connector
1. The alarmed video signal is output from
the Alarm Spot Output Connector (11),
Other WJ-SQ308s go to sequence. (The
spot operation is available for 1-ch - 8-ch)
2. The alarmed video signal is output from
the Alarm Spot Output connector (11). All
Other WJ-SQ308s go on the sequence.
1. The WJ-SQ308 (D) supplied with the
alarm signal is switched to the alarm pic
ture.
All
other
WJ-SQ308S
go
to
sequence. (The spot operation is available
for 1-ch - 8-ch)
2. The WJ-SQ308 (D-B) supplied with the
alarm signal is switched to the alarm pic
ture. All Other WJ-SQ308S go to sequenc
ing with the switching time set by the tim
ing pulse from VCR.
Alarm mode (multiple input)
In case of alarm input to the (C-
B or D-B)
1. Alarm/Spot Output Connec
tor
2. Alarm/Sequential Output
Connector
The alarm timing of the WJ-SQ308 (C-C).
supplied
the alarm input
signal,
is
sequenced with the timing of WJ-SQ308
All Other WJ-SQ308s go for sequence.
(The spot or bypass operation is avail
able for 1-ch - 8-ch)
The alarm timing of the WJ-SQ308 (C-B),
supplied
the alarm input
signal,
is
sequenced with the timing of Master WJ-
SQ308 All other WJ-SQ308s go to
sequence.
(The bypass operation is
available for 1-ch - 8-ch)
1. The alarm timing of, the WJ-SQ308 (D-B)
supplied
the
alarm
input
signal,
is
sequenced with the timing pulse from
VCR. All Other
\A/J-SQ308s go
to
sequence. (The spot or bypass opera
tion is available for 1-ch - 8-ch)
2. The alarm timing of, the WJ-SQ308 (D-B)
supplied with the alarm input signal, is
sequenced with the timing pulse from
VCR. All Other
WJ-SQ308S
go
to
sequence.
(The
bypass
operation
is
available for 1-ch - 8-ch)
Notes:
The switching interval of VCR and Camera should be 0.3 seconds or more.
Each screen of video monitors are not same with the camera screen.
A Time Lapes VTR may be connected to each WJ-SQ308.
-
9
-