Do not connect the intercom system of AC power source.
Two modes for the Alarm Control Out are selected.
STD BY: This terminal is performed at only Standby mode
of the Mode Selection Switch when the SPOT MONI
TOR CONTROL IN is activated by intercom or alarm
sensor/switch.
ALL MODE: This terminal is performed at either Standby or
On Mode of the Mode Selection Switch when the SPOT
MONITOR CONTROL IN is activated by intercom or
alarm sensor/switch.
The polarity for the alarm and Alarm Control Output of the
monitor should be matched.
The power rate of the alarm should be DC24V, max.
100mA.
If the power capacity of the alarm is less than 100mA at DC
24V, the alarm can be connected at the terminal of Alarm
Control Out directly.
If the power capacity of the alarm is more than 100mA at
DC24V, the alarm can not be connected at terminal direct
ly. In this case, the relay circuit should be used for the
alarm.