11 specifications, 1 dynamometer specifications, Chapter 11 specifications – Dillon EDXtreme (Old) User Manual
Page 46: Dynamometer specifications
46
EDxtreme User Instructions
11 Specifications
11.1 Dynamometer Specifications
Enclosure:
Designed to NEMA4X/IP55. Suitable for continuous outdoor use.
Accuracy:
0.1% of capacity.*
0.3% of capacity for EDX 75t and above*
Repeatability:
0.1% of capacity.
0.3% of capacity for EDX 75t and above*
*1 part in 1000 display mode with Dillon provided shackles.
Factor of safety: 2.5K to 10K = 7:1 USF
25K to 100K = 5:1 USF, 220K to 330K 4:1 USF
Body Protection: Powder painted aluminum or steel bodies.
Bearings: Unmatched
repeatability
attained by needle bearings in shackle pin holes up to EDX-10K.
Shackle pin acts as inner race.
Shackles:
Forged industry standard anchor shackles. Models up to EDX-10K use precision machined
shackle pin. Higher capacities use forged pin.
Display:
128 x 64 dot-graphic LCD display shows up to 6 digits 1.0” (26mm) high plus annunciators
and soft keys. Digits are .11 inches (3mm) thick for unmatched readability.
Display update rate: 2 times per second.
Peak capture rate: 60 times per second
Connector:
Recessed sealed connector may be used for serial communications or connection to a
Communicator remote.
RS-232 / RS-485 communication: Print or extract data easily. Continuous output can drive a scoreboard.
Configurable poll character.
Calibration:
Traceable to the National Institute of Standards and Technology. Certificate included with
curve of readings. Passes only with three consecutive confirming runs, with all points in
specification.
Battery life:
320 hours typical use with two C-cell alkaline batteries. 40 hours typical with Radio Link
system.
Operating temperature: -4° F to 140° F (-20° to 60° C)
Included with instrument: Carry case, batteries, manual and certificate of calibration. EDX-50K and EDX-
100K with shackles include shackle crate and spacers.
Options:
Shackles, 2.4 GHz radio board, Display backlight.