EDxtreme User Instructions

27

5.

Select a parity value using the Sel keys to scroll through your choices.
Choices are none (default), odd and even. Press Enter to accept the setting.

The following display appears:

6.

Select a databit value using the Sel keys to toggle between the two choices; 7
or 8 (default). Press Enter to accept the setting.

The following display appears.

7.

Select a mode of communication you want using the Sel keys to scroll through
these choices; Continuous, Poll, Remote and Print Key Only. Press Enter to
accept the setting.

If you choose Continuous, you will be prompted to select a print format
for the transmission and a rate at which you want to send the
transmission.

If you choose Poll you will be prompted to enter a poll character. Enter
the ASCII value of the poll character.

Choose Remote for wireline communications to the Communicator and
Trans Level (*RS485)

Choose Print Key Only to print only when the Print key is pressed.

8.

Press ESC to return to the first soft key set of the Configuration menu.

Default Serial Communications
Baud Rate = 57600
Parity =

None

Databits =

8

Stop bits =

1

There is no option for handshakes. All settings should be None.