Parameter
Specification
Limit
Units Conditions/Comments
I/O: Type
RS-485
Euroblock connector
..........Impedance
12k
min
Ω
Receive Mode
..........Baud Rate
38400
<1%
bps
RW 485 baud rate
9600
<1%
bps
Programmable
19200
<1%
bps
Programmable
57600
<1%
bps
Programmable
115200
<1%
bps
Programmable
..........Data Format
N81
No parity, 8 data bits, 1 stop bit
Power Supply Requirement
7 minimum, 16 maximum
min
VDC
DC voltage @ +V referenced to -V
RW 485 Drive Current
28
+1
mA
No termination, communication active.
One remote per bus active at a time.
SR 4: Supply Current
52
+5
mA
Communication idle
SR 3: Supply Current
50
+5
mA
Backlight off, communication idle
95
+5
mA
Backlight max brightness, communication idle
SR 2: Supply Current
42
+4
mA
Communication idle
All Units:
Agency Listing
CE (EMC)
EMC directive 89/336/EEC
CE (safety) Exempt
Exempt per article 1, LVD 73/23/EEC
..........Construction
Steel
Chassis
Polycarbonate
Lens
SR 2 / SR 4: Size
4.1" H x 1.7" W x 2.8" D
(10.4 cm x 4.3 cm x 7.1 cm)
SR 3: Size
4.1" H x 1.9" W x 2.8" D
(10.4 cm x 4.8 cm x 7.1 cm)
All Units:
Weight
8 oz
(.23 kg)
.....Shipping: Size
3.6" H x 11.75" W x 7.2" D
(9.2 cm x 30 cm x 18 cm)
..........Weight
1 lb 8 oz
(.69 kg)