beautypg.com

Manual-26 – Rane SR 2 User Manual

Page 26

background image

Manual-26

IF
Input Force

Forces new main level and second level. Resets the command state to No Operation.

The main level is updated and indicated by the LED regardless of Auto Level configu-

ration.

If Auto Second Level is enabled, the second level is updated and indicated by the

flashing LED. Otherwise, if Auto Second Level is disabled, the second level is up-

dated.

Send: IF,n1,n2

Where: n1 is the new main level. The main level range is [0, 31].

If n1 is zero, the main level remains unchanged.

n2 is the new second level. The second level range

is [0, 31]. If n2 is zero, the second level remains

unchanged.

Example: IF,3,5 sets a new main level of 3 and a new second level

of

5.

Response: "OK"