Cable Type 1

2 twisted pair unshielded CAT 5, Belden #1588(A,R)
2 twisted pair unshielded CAT 5, Belden #1590A

Note: This table is only for systems using SR 2 remotes (all remotes on 485 bus are
the same). For mix and match calculation of SR 2, SR 3 and SR 4 Remotes, use the
SRCABLELENGTH.XLS Microsoft Excel™ spreadsheet on the Drag Net CD-ROM or
at www.rane.com/sr2.html.

Requires

external

supply

Max Distance

for Cable (feet)

Max Distance for

Cable (meters)

Number of

SR 2 Remotes

Vs = 15V

RPM 44

RPM 22

1000

305

1

1000

305

2

921

281

3

722

220

4

594

181

5

504

154

6

438

134

7

388

118

8

Vs = 12V

RPM 88

1000

305

1

795

242

2

576

176

3

451

138

4

371

113

5

315

96

6

274

84

7

242

74

8

Vs = 8V

256

78

1

159

48

2

115

35

3

90

28

4

74

23

5

63

19

6

55

17

7

48

15

8