beautypg.com

Orthogonal assembly – Pilz PSEN cs4.2a User Manual

Page 16

background image

PSEN 4.2a/b/p/M12

Operating Manual PSEN 4.2a/b/p/M12
22188-EN-02

16

1. Do not fully tighten the 2nd screw on the

safety switch.

2. Attach the screws for the actuator, leav-

ing a distance of 3 … 6 mm between the
screw head and plate.

For the next steps you will need the seals as

illustrated.

Use the seals (2) to close the unused

mounting holes on the actuator.

Slide the actuator on to the screws.

Align the actuator and tighten the screws.

Use the seals to close the screws' mounting

holes on the actuator

}

(4): Without UL approval

}

(1): For UL approval

Use the seals (3) to close the mounting

holes on the sensing face of the safety

switch.