beautypg.com

Dvrt41direct vent gas fireplace – Vermont Casting DVRT41 User Manual

Page 37

background image

37

DVRT41Direct Vent Gas Fireplace

10006740

LOCAL

Center
Plunger

Blue -
NG

Red - LP

Motor Top Cap

FP1037b

Fig. 65 Depressd and turn center plunger.

Fig. 67 Burner orifice replacement.

CO124

Rear Burner Orifice:
Refer to Conversion Kit
Orifice Chart

Front Burner Orifice:
Refer to Conversion Kit
Orifice Chart

15.Turn the gas supply valve and gas valve on and test

for leaks. Use a 50/50 solution of liquid soap and
water to test for leaks at gas fittings and joints. Apply
water/soap solution with brush only -

do not over

apply. NEVER test with an open flame.

16.Follow procedure on rating plate to light the pilot.

Check for leaks.

17.Turn main burner on and check for leaks.

18.Install logs. Refer to Page 24 for proper log place-

ment.

Installation complete.

Fig. 68 Remove air shutter from burner pan.

Shutter
Retaining
Screw

Burner Pan

Air Shutter

Front View

CO103

Pilot Hood

Index
Marks

Pilot
Bracket

CO105

Fig. 69 Remove pilot hood.

10.Reinstall manifold mounting screw.

NOTE: It is not necessary to remove the pilot tube for

conversion.

11. Loosen pilot hood turning counterclockwise using a

7/16” wrench. (Fig. 69)

12. Remove pilot orifice with needlenose pliers. (Fig.

70)

13. Install conversion pilot orifice.

14. Reinstall pilot hood. Be sure to align pilot hood with

index marks.

Pilot Orifice

CO106

Fig. 70 Remove pilot orifice.

Manifold
Assembly

Orifice

Fig. 66 Remove manifold assembly.

CO101a

Burner Pan

Pilot Location

Manifold Mounting
Screw