beautypg.com

Dvrt41direct vent gas fireplace, Local path, On path – Vermont Casting DVRT41 User Manual

Page 31

background image

31

DVRT41Direct Vent Gas Fireplace

10006740

Light pilot burner

Set manual switch

to local or remote

Release pilotstat

knob

Turn pilotstat knob

from PILOT to ON

If manual switch is

set to LOCAL, did

main burner light?

Transmitter

controls fan

Turn pilotstat knob

to PILOT to turn

off main burner

Turn pilotstat knob

to OFF to turn

valve completely

off

Comfort Valve system control sequence of operation with transmitter

Did the LED stop

blinking?

Review LED

failure analysis

Five minute wait

period

Cycle switch once

and leave in

remote. Press any

key on transmitter

for recognition

operation

Local Path

Move switch from

local to remote.

Press any key on
transmitter. Move

switch back to

local

Yes

Yes

If the manual switch

is set to REMOTE,

press the mode

button to display

"ON". Does transmit-

ter control the main

burner and fan?

Does transmitter

change levels of

flame height, fan

speed and set

temperature?

Set levels of flame

height and fan to

“0” to shut off main

burner and fan

Turn pilotstat knob

to OFF to turn

valve completely

off

On Path

Move switch from

manual to remote.

Press any key on

transmitter.

Yes

Yes

No

No

Choose Local or

Remote path. Set

switch to manual or

remote

Yes

Yes