beautypg.com

Dvrt41direct vent gas fireplace – Vermont Casting DVRT41 User Manual

Page 27

background image

27

DVRT41Direct Vent Gas Fireplace

10006740

Lighting & Operating Instructions

For Fireplaces equipped with SIT822 Gas Valve (EN or EP)

A. This fireplace is equipped with an ignition device

which automatically lights the pilot. DO NOT try to
light the pilot by hand.

B. BEFORE OPERATING, smell all around the

appliance area for gas. Be sure to smell next to
the floor because some gas is heavier than the air
and will settle on the floor.
What to do if you smell gas

Do not try to light any appliance.

Do not operate any electrical switch.

Do not use any phone in your building.

Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
suppliers instructions.

For Your Safety, Read the Following Warnings

before Lighting the Appliance

If you cannot contact your gas supplier call
the Fire Department

C. Use only your hand to push in or turn the gas

control knob. Never use tools. If the knob will not
push in or turn by hand do not try to repair it, call a
qualified service technician. Force or attempting
repair may result in a fire or explosion.

D. Do not use this appliance if any part has been

under water. Immediately call a qualified service
technician to inspect the appliance and replace
any part of the control system and any gas control
that has been under water.

5. Turn the remote switch, if used, OFF. Turn the

wireless remote, if used, OFF.

6. Wait five (5) minutes to clear out any gas. Then

smell for gas, including near the floor. If you
smell gas, STOP. Follow instruction B in the
safety warnings above. If you do not smell gas,
go on to the next step.

7. Close the access door.

8. Turn ON all electrical power to the appliance.

9. Turn remote switch or wireless remote to ON.

10. If the appliance will not operate, follow the

instructions TURNING OFF THE GAS TO THE
APPLIANCE, and call your service technician or
gas supplier.

1. Turn the remote switch to the OFF position.

2. Turn OFF all electrical power to the fireplace if

service is required.

3. Open the lower access panel.

4. Turn the shut-off valve on the flexible gas line to

the OFF position.

FP297A

Warning:

If you do not follow these instructions exactly, a fire or explosion may
result, causing property damage, personal injury and loss of life.

Lighting Instructions

Turning Off the Gas to the Appliance

HI

LO

1. STOP! Read the safety information above

before continuing.

2. Turn off all electrical power to the appliance.

3. This appliance is equipped with an ignition device

which automatically lights the pilot. DO NOT try
to light the pilot by hand.

4. Access the gas control by lowering the lower

access door (louvre assembly).

1/2” Gas Supply

1/2” NPT x 1/2” Flare
Shut-Off Valve

3/8” Flex Line
(From Valve)

Valve in the “ON” position