Tycon Power TP2700WC User Manual
Page 15
15
g) ABS PRESS CORRECT
Absolute pressure can be calibrated within measuring range.
h) REL PRESS CORRECT
Relatively pressure be calibrated within measuring range.
i)
WIND DIR CORRECT
Wind direction can be adjusted by 0-359°.For southern hemisphere installations, the wind
direction need to change by 180°.
j)
WIND FACTOR
Wind speed calibration coefficient: default 1 (range is Range is 0.1-2.5)
k) RAIN FACTOR
Rain factor calibration coefficient: default 1 (range is Range is 0.1-2.5)
l)
RAIN DAY CORRECT
Calibration for total rain falls of 1 day. (Range is 0-9999mm)
m) RAIN WEEK CORRECT
Calibration for total rain falls of 1 week (Range is 0-9999mm)
n) RAIN MONTH CORRECT
Calibration for total rain falls of 1 month (Range is 0-9999mm)
o) RAIN YEAR CORRECT
Calibration for total rain falls of 1 year (Range is 0-9999mm)
p) RAIN TOTAL CORRECT
Calibration for total rain falls since last reset. (Range is 0-9999mm)
Transmitter ID
Display the transmitter ID.
2.2 ALARM SETTING MODE
In normal mode, press ALARM key you will enter high alarm mode, and press ALARM key
again you will switch to low alarm mode.
HIGH ALARM SETTING
Press Left/Right key to transfer among the different segments and press +/- key to adjust the
value of the high alarm.
a) TIME ALARM
– Set time alarm.