PPU-231 User’s Manual
51
CITIZEN
ESC
= n
[Function]
Data Input Control
[Code]
<1B>H<3D>H
[Range]
{0
≤ n ≤FF} Data is described in Hex code.
[Outline]
Selecting equipment in which data input from the host is effective.
• Each bit of n indicates as follows:
Value
Bit Equipment
0 1
0 Printer Invalid
Valid
1 Not
defined
2 Not
defined
3 Not
defined
4 Not
defined
5 Not
defined
6 Not
defined
7 Not
defined
• When the printer has not been selected, this printer abandons all the received data
until it is selected by this command.
[Caution]
• Even when the printer has not been selected, it can become BUSY state
through printer operation.
• When the printer is deselected, this printer discards all the data until it is
selected with this command.
[Default]
• The initial value of n is "1".
[Sample Program]
LPRINT "AAAAA" ;
LPRINT CHR$ (&H1B) + "=" + CHR$ (0) ;
LPRINT "aaaaa" + CHR$ (&HA) ;
LPRINT CHR$ (&H1B) + "=" + CHR$ (1) ;
LPRINT "AAAAA" + CHR$ (&HA) ;
[Print Results]