3 input and output signals, 1 input and output signals – CITIZEN PPU-231 User Manual
Page 41
![background image](/manuals/64081/41/background.png)
PPU-231 User’s Manual
28
CITIZEN
6.3
Input and Output Signals
6.3.1
Input and Output Signals
(1) Input signals to the printer
• DATA
: 8-bit parallel signal (Active: “High”)
• STROBE : Strobe signal to read the 8-bit data (Active: “Low”)
• RESET
: Signal to reset the entire printer (Active: “Low”); 1 ms or more
(2) Output signals from the printer
• ACK
: 8-bit data request signal. A pulse signal to be output at the end of the BUSY signal
(Active: “Low”)
• BUSY
: Signal to indicate that the printer is busy. Input new data when it is "Low."
(Active: “High”)
• FAULT
: Turned to "Low" when the printer has an alarm. At this time, all the control circuits in
the printer stop. (Active: “Low”)
• PE
: Output if the printing paper has run out or is running out. (Active: “High”)