7.1 Specifications
(1) Synchronous
system
: Asynchronous
(2) Baud rate
: 1,200, 2,400, 4,800, 9,600, 19,200 bps (Selected by the user)
(3) 1-word
configuration
Start bits
: 1 bit
Data bits
: 8 bits or 7 bits (Setting upon shipment)
Parity bits
: Odd, even, or no parity (Selected by the user)
Stop bits
: 1 bit or more
(4) Signal
polarity
RS-232C
• Mark
= Logic "1" (-3
∼ -12 V)
• Space
= Logic "0" (+3
∼ +12 V)
(5) Received data (RXD signal)
• Mark
= 1
• Space
= 0
(6) Reception control (DTR signal)
• Mark
: Data not transferable
• Space
: Data transferable
(7) Transmission control (TXD signal)
• DC1 code(11H) X-ON
: Data receivable
• DC3 code(13H) X-OFF
: Data not receivable
7.2
Connector's Pin Configuration
No. Signal
Name Input/Output
Function
1 FG
Frame
Ground
7 GND
Signal
Ground
3 RXD
Input
Received
Data
20
DTR
Output
Printer BUSY Signal
2 TXD
Output
Transmitted
Data
6
DSR
Input
Data Set Ready
[Note] 1. The RS-232C signals are based on the EIA RS-232C.
2. The received data should be always maintained in the Mark status when no data is being
transferred.
Applicable connectors (D-Sub connectors)
Printer side
: 17LE-13250 (Anphenol) or its equivalent
Cable side
: 17JE-23250 (Anphenol) or its equivalent