7. SERIAL

INTERFACE

7.1 Specifications

(1) Synchronous

system

: Asynchronous

(2) Baud rate

: 1,200, 2,400, 4,800, 9,600, 19,200 bps (Selected by the user)

(3) 1-word

configuration

Start bits

: 1 bit

Data bits

: 8 bits or 7 bits (Setting upon shipment)

Parity bits

: Odd, even, or no parity (Selected by the user)

Stop bits

: 1 bit or more

(4) Signal

polarity

RS-232C

• Mark

= Logic "1" (-3

∼ -12 V)

• Space

= Logic "0" (+3

∼ +12 V)

(5) Received data (RXD signal)

• Mark

= 1

• Space

= 0

(6) Reception control (DTR signal)

• Mark

: Data not transferable

• Space

: Data transferable

(7) Transmission control (TXD signal)

• DC1 code(11H) X-ON

: Data receivable

• DC3 code(13H) X-OFF

: Data not receivable

7.2

Connector's Pin Configuration

No. Signal

Name Input/Output

Function

1 FG

Frame

Ground

7 GND

Signal

Ground

3 RXD

Input

Received

Data

20

DTR

Output

Printer BUSY Signal

2 TXD

Output

Transmitted

Data

6

DSR

Input

Data Set Ready





[Note] 1. The RS-232C signals are based on the EIA RS-232C.

2. The received data should be always maintained in the Mark status when no data is being

transferred.

Applicable connectors (D-Sub connectors)

Printer side

: 17LE-13250 (Anphenol) or its equivalent

Cable side

: 17JE-23250 (Anphenol) or its equivalent