Rice Lake MSI-4260 Port-A-Weigh User Manual
Page 58

54 MSI-4260 Port-A-Weigh Operator’s Manual
Display toggle between
“Error” and “UnLd”
Weight in below the zero
range.
If scale is in compression, remove
the source.
Calibration faulty
Recalibrate
Faulty Load Cell or wiring Check load cell connections
Display toggles
between “Error” and
“A2DLo”
A/D is saturated negative
Check load cell and load cell
wiring
Display toggles
between “Error” and
“buttn”
A key is stuck or is being
held down
Check switches for damage
Ensure that a remote is not
transmitting continuously
RF Remote does not
work
Units not mated
See Section 6.3 and Section 6.4.
Some RF Remote keys
do not work but the
ACK light blinks
Keys were not enabled
during the setup process
Enable keys by running the
transmitter and receiver address
procedures
Lo Batt is blinking
Battery is low
Recharge Battery
Unit turns on, then
immediately off
Battery is low
Recharge Battery
Weight will not zero
System not stable
Stable annunciator must turn on
for Zero to function. Increase
filtering for more stability.
Increase filtering for more stability
Zero out of range
LFT units have limited zero range.
Reduce the weight or use Tare
instead
Weight will not Zero,
Tare or Total
System is not stable
Wait for Stable annunciator to
turn on, or if in a mechanically
noisy crane, increase the filtering
or increase the size of the scale
increment ‘‘d’. It is also possible
to increase the motion window.
Contact MSI if you have a
problem getting the MSI-4260 to
zero, tare, or total due to stability
issues.
Set Point Lights Blink
Set point is enabled and
the trigger point has been
reached
Disable set points if they are not
needed
Manual Total does not
work
A Function key is not set
to “Total”
Set up Func1 or Func2 for “Total”
Weight must be stable
Increase filtering for more stability
Problem
Possible Cause
Solution
Table 8-1. Troubleshooting