Figure 3-6 shows the configuration me nu, Laser lt – Rice Lake Remote Displays/Scoreboards - Laser LT User Manual
Page 19

Configuration
15
Figure 3-6 shows the Configuration menu.
PRI CHR
L=76
PRI LOC
000000
SEC CHR
K - 75
SEC LOC
000000
GRS CHR
G - 71
GRS LOC
000000
LOCK
On
Off
LW POS
000000
NODATA
No Com
Blank
STDSTL
On
Off
SP IND
COZ LOC
000000
COZ CHR
Z - 90
On
Off
DWM4 1
Toledo
None
LB-OZ
F2500
SCHAR
STX
SOH
CR
LF
FF
ETX
SERIAL
TEST
KEYPAD
DIGIO
VERS
CONFIG
E CHAR
LF
CR
FF
ETX
HOLD WT
SUPP 0
Off
On
NET LOC
000000
MOT LOC
000000
NEG LOC
000000
OVR CHR
O - 79
NET LOC
000000
MOT CHR
M - 77
OVR LOC
000000
NEG CHR
[-] 45
N - 78
NET CHR
Figure 3-6. Configuration Main Menu Choices
CONFIG Menu
Parameter
Choices
Description
Level 2 Submenus
HOLD WT
Off
On
Select On to enable this feature to keep the last weight displayed if
communication is lost or when using demand updated weight to prevent the
remote display from going into a NO DATA error condition.
STDSTL
Off
On
Select On to blank the display when the scale is in motion.
NO DATA
No Com
Blank
Selects what to display when the
Laser LT
is not receiving recognizable data -
“NO COM” or blank screen.
LOCK
Off
On
Select On to make sure the current settings don’t get changed and to disable
Auto-Learn. When off, the system enables Auto-Learn.
S CHAR
STX
CR
SOH
LF
FF
ETX
The
Laser LT
scans for this character to determine the start of a packet.
Table 3-2. Configuration Menu Summary - Level 2