Configuration
13
Use the following quick steps for Auto-Learn.
1. Ensure that
Lock
in Configuration mode is set to the
Off
position.
LOCK
On
Off
LW POS
000000
NODATA
No Com
Blank
STDSTL
On
Off
On
Off
SCHAR
STX
SOH
CR
LF
SERIAL
TEST
KEYPAD
DIGIO
VERS
CONFIG
E CHAR
LF
CR
FF
ETX
HOLD WT
SUPP 0
Off
On
Figure 3-2. Lock Parameter Location
2. Set up the Host Port.
3. Enter the Auto-Learn feature from Run Mode by pressing and holding the
Gross/Net
key for three seconds.
4. If this does not work, and Learn fails, use Revolution Utility software (Section 3.10 on page 24).
Note
•
It is recommended to set the parameter lock to the On position (see Table 3-4), to eliminate any un-intentional
changes from occurring.
•
If the displayed weight is not correctly positioned, press and hold the right (unit) and left (print) buttons for three
seconds then release, to shift the displayed data string. The data will move one position. Repeat this as many
times as necessary to move the data over another position.
3.2
Manual Configuration
To begin configuration, open the enclosure to access the CPU board (Figure 3-3).
Setup
Button
Figure 3-3. Laser LT CPU Board
The setup button is located on the CPU board (Figure 3-3).This allows access into Configuration Mode.
Press the
SETUP
button to access main menu configuration parameters.