2 format menu, Format menu, 2 format menu figure 3-7. format menu – Rice Lake IQ plus 2100SL Digital Bench Scale User Manual
Page 13: Config menu

Configuration
15
3.2.2
Format Menu
Figure 3-7. Format Menu
OVRLOA
FS+2%
FS+1D
FS+9D
FS
Overload. Determines the point at which the display blanks and an out-of-range error
message is displayed. Maximum legal value varies depending on local regulations.
FILTER
4
8
16
4RT
8RT
16RT
1
2
Digital filtering. Selects the digital filtering rate used to reduce the effects of mechanical
vibration from the immediate area of the scale.
Choices indicate the number of A/D conversions that are averaged to obtain the
displayed reading. A higher number gives a more accurate display by minimizing the
effect of a few noisy readings, but slows down the settling rate of the indicator. Values
with the RT suffix provide a raised threshold for filtering larger noise spikes.
CONFIG Menu
Parameter
Choices
Description
Table 3-2. Configuration Menu Parameters (Continued)
KG
G
OZ
LB
PRIMAR
ALTUNT
DSPDIV
UNITS
DECPNT
OZ
KG
88888.8
8888.88
1D
5D
2D
LB
88.8888
8.88888
888880
888888
OFF
ON
LB/OZ
G
LB/OZ
XXXXXXX
XXXXXXX
VERS
DEFLT
DIG IN
SERIAL
CALIBR
CONFIG
FORMAT
OFF
ON
OFF
ON
OFF
ON
OFF
ON
888 88
88 88.8
If UNITS=LB/OZ,
DECPNT selections are:
888.888