Tracer AV Installation Manual
Level 3 submenus
Primary Units (PRIMAR Parameter)
DECPNT
88888.8
888888
888880
8.88888
88.8888
888.888
8888.88
Decimal point location. Specifies the location of the decimal point or dummy zeroes in the
primary unit display. Value should be consistent with local legal requirements.
DSPDIV
5D
1D
2D
Display divisions. Selects the minimum division size for the primary units displayed weight.
UNITS
LB
KG
OZ
TN
T
G
NONE
Specifies primary units for displayed and printed weight. Values are: LB=pound;
KG=kilogram; OZ=ounce; TN=short ton; T=metric ton; G=gram
NOTE: Indicators sold outside North America are configured with KG for both
primary and secondary units.
Secondary Units (SECNDR Parameter)
DECPNT
88888.8
888888
888880
8.88888
88.8888
888.888
8888.88
Decimal point location. Determines the location of the decimal point or dummy zeros in
the secondary unit display.
DSPDIV
5D
1D
2D
Display divisions. Selects the value of minimum division size of the displayed weight.
UNITS
KG
OZ
TN
T
G
NONE
LB
Specifies secondary units for displayed and printed weight. Values are: KG=kilogram;
OZ=ounce; TN=short ton; T=metric ton; G=gram; LB=pound.
MULT
0.453592
Enter other
choices via
keyboard
Multiplier. Specifies the conversion factor by which the primary units are multiplied to
obtain the secondary units. The default is 0.453592, which is the conversion factor for
changing pounds to kilograms. See Section 6.5 on page 36 for a list of multipliers.
NOTE: Multipliers are pre-configured within the indicator. Manual entry is only
necessary when NONE is selected under UNITS.
To toggle between primary and secondary units, press the Units key.