beautypg.com

2 configuration menu, Configuration menu, Table 3-4. configuration menu parameters – Rice Lake Tracer AV User Manual

Page 17

background image

Tracer AV Installation Manual - Configuration

13

3.2.2

Configuration Menu

Figure 3-5. Configuration Menu

CONFIG Menu

Parameter

Choices

Description

Level 2 submenus

GRADS

1000
number

Graduations. Specifies the number of full scale graduations. The value entered must be in
the range 1–100 000 and should be consistent with legal requirements and environmental
limits on system resolution.

To calculate GRADS, use the formula, GRADS = Capacity / Display Divisions.

Display divisions for primary and secondary units are specified on the FORMAT menu.

ZTRKBN

0
number

Automatically zeroes the scale when within the range specified, as long as the input is
within the ZRANGE and scale is at standstill. Specify the zero tracking band in ± display
divisions. Maximum legal value varies depending on local regulations.

NOTE: For scales using linear calibration, do not set the zero tracking band to a value
greater than that specified for the first linearization point.

ZRANGE

1.900000
number

Selects the range within which the scale can be zeroed. The 1.900000 default value is ±
1.9% around the calibrated zero point, for a total range of 3.8%. Indicator must be at
standstill to zero the scale. Use the default value for legal-for-trade applications.

Table 3-4. Configuration Menu Parameters

XXXXXXX

XXXXXXX

GRADS

1000

ZTRKBN

ZRANGE

1.900000

MOTBAN

FS+2%

FS+9D

FS+1D

FS

OVRLOA

1

4

2

8

DIGFL1

32

16

64

1

4

2

8

32

16

64

1

4

2

8

32

16

64

number

DIGFL2

DIGFL3

BOTH

PBTARE

NOT

ARE

KEYED

T AREFN

SETPNT

PROGRM

SERIAL

CALIBR

CONFIG FORMAT

8OUT

32OUT

16OUT

64OUT

DFSENS

DFTHRH

2OUT

128OUT

4OUT

2DD

NONE

5DD

20DD

10DD

50DD

200DD

100DD

250DD

15HZ

60HZ

30HZ

7.5HZ

SMPRAT

VERS

DEFCAL

0

1

number

number

number

This manual is related to the following products: