Pausing/Resume/Reset a Dispense
19
Figure 4-12. Dispense Screen
The three dispensing speeds include:
• Single speed dispensing - The system turns on fast dispense until the target weight/preact weight is
satisfied.
• Parallel speed dispensing - Turns on the fast dispense and slow dispense until the dribble weight is
satisfied. The system then turns off the fast dispense and leaves the slow dispense on until the target
weight/preact weight is satisfied.
• Dual speed dispensing - Turns on the fast dispense until the dribble weight is satisfied. The system turns
on the slow dispense until the target weight/preact weight is satisfied.
The system does the following when the target/preact is reached.
• Turns off the output based on the dispensing mode
• Update the subtotal weight and number of dispenses
• Updates the total and number of dispenses
• Turns on the Dispense Complete output
The system delays for the Delay After Dispense time. After the delay, the weight display then switches to gross
weight and:
• If the gross weight is below low level weight the Refill output will automatically turn on until the gross
weight exceeds the high level weight.
• If the gross weight is above low level weight system, the system resets for the next cycle beginning with
Step #1.
4.4
Pausing/Resume/Reset a Dispense
1. Press the E-Stop button. System turns off all outputs and displays
System Paused
.
2. Press the
Resume
switch to resume where the current batch left off.
Press the Reset switch to return back to Step 1 to start over.
250
Target
Dribble
Preact
High Level
Consec. #
Subtotal
Total
100.0 Lb
75
0.0
500 Lb
2
120 Lb
3200 Lb
05/20/2011
10:28AM
SCALE #1
SCALE
#1
Gross
Lb
Low Level
150 Lb
Fast Dispense