3 dispensing material from a scale – Rice Lake 920i FlexWeigh Systems - 103 User Manual
Page 22

18
System 103 Loss-in Weight Dispensing Controls
Print Total
1. Press the
Totals
softkey (Figure 4-8) to access the
Print Total
softkey.
2. Press the
Print Total
softkey to access the following screen.
Figure 4-11. Clear Total Screen
3. Press the
Yes
softkey to clear the total and sub-total of the batch.
Press the
No
softkey to exit out of the screen.
4.3
Dispensing Material from a Scale
1. Press the
Start
button on the unit. The system verifies if:
• E-Stop is pulled out
• A valid target weight is entered
The system verifies the weight to make sure it’s above the target weight and above the low level weight. If
the weight is below the low level weight, it will refill the scale to the high level weight. When the weight
reaches the high level weight, the refill output will turn off.
2. Press the
START
button to start the dispensing material.
The system does the following during this process.
• Turns off the Dispense Complete and Refill Complete outputs
• Increments the consecutive number by one
• Tares the scale to zero (net mode)
The system begins dispensing either of three speeds while the 920i screen displays real time sequence
progress. The displayed net weight will continue showing more negative as weight is dispensed, until the
target weight presets are achieved.
- - - - -
Target
Dribble
Preact
High Level
Consec. #
Subtotal
Total
100.0 Lb
75
0.0
500 Lb
2
0.0 Lb
0.0 Lb
Yes
No
05/20/2011
10:31AM
SCALE #1
SCALE
#1
Gross
Lb
Low Level
150 Lb
Clear Total?