FG-3223
ANCHOR SUB-SILL WITHIN 4" FROM EITHER
SIDE OF INTERMEDIATE MULLIONS ANCHOR
SIZE AND FREQUENCY SHOULD BE
DETERMINED BY STRUCTURAL REQUIREMENTS.
CAP SEAL ANCHORS AS SHOWN.
SEAL END DAM TO
SUB-SILL.
SHIM UNDER
SUB-SILL.
INSTALL SUB-SILL AND END DAM
INSTALL SPLICE SLEEVE
NOTE:
1) SUB-SILL SHALL BE INSTALLED
LEVEL AND SHOULD NEVER TILT
TOWARDS INTERIOR OF BUILDING.
2 REFERENCE PAGE 43 FOR END REACTIONS
FOR SPECIFIC SILL ANCHORS.
3) SPLICE SUB-SILL AT MID-LITE ON LONG RUNS.
FG3000-FP-10
1/4" NOMINAL
SEAL WITH A NON-SKINNING
NON-HARDENING SEALANT.
FILL BREAK IN FLASHING
AND UNDER SPLICE.
FG3000-FP-4
SEAL SUB-SILL SPLICE JOINTS
UP VERTICAL LEG OF FLASHING AND
MARRY INTO PERIMETER SEAL.
INSTALLATION INSTRUCTIONS FOR
FG-3223 SUB-SILL
CLEAN EXCESS
SEALANT AFTER
INSTALLATION OF
SYSTEM.
SEAL SUB-SILL VERTICAL
SPLICE JOINT
JUST PRIOR TO FRAME INSTALLATION,
APPLY CONTINUOUS SEALANT ALONG
GROOVE IN BACK LEG OF SUB-SILL.
IMMEDIATELY INSTALL FRAME INTO SILL.
FG3000-FP-9
DETAIL "A"
DRILL 1/4" WEEP HOLES
LOCATE AT MID-LITE