S E R I E S 3 0 0 0 T H E R M A L M U L T I P L A N E I N S T A L L A T I O N M A N U A L

C

C

NOTE: 1/4" WEEP HOLES

REQUIRED IN FLASHING (E)

AT CENTERLINE OF D.L.O.

APPLY SEALANT ALONG LENGTH OF SILL FLASHING AT POINT (A).

WHEN USING OPTIONAL FG-3413 SILL RECEPTOR:

ONCE THE WALL IS SECURED, APPLY FILLET SEAL BETWEEN SILL FLASHING

AND FRONT OF SILL (B).

THE QUALITY OF THE INSIDE AND OUTSIDE PERIMETER SEALS (C) MAY BE

IMPROVED

BY USING FG-2188 RIGID PVC FILLER. THE PART MAY BE USED IN FULL

LENGTHS OR CUT INTO PIECES. ITS PURPOSE IS TO PROVIDE SUPPORT FOR

THE BACKER

ROD REGARDLESS OF JOINT SIZE. INTERIOR PERIMETER SEAL AT SILL (D)

IS FOR COSMETIC PURPOSES AND IS OPTIONAL.

FOR SSG INSTALLATION ONLY. INTERIOR PERIMETER SEALS "C" & "D" ARE

FOR COSMETIC PURPOSES AND ARE OPTIONAL.

C

B

A

E

D

A

C

C

A

E

D

A

C

C

C

SHOWN WITH OPTIONAL SILL

C

C

FG-2122

CUT 4" LONG

(SOLD IN STOCK

LENGTHS)

A

D

A

E

INSIDE GLAZED

ANCHORAGE AND PERIMETER SEAL