beautypg.com

Measuring-cutting – Oldcastle BuildingEnvelope 3000 Series Thermal MultiPlane User Manual

Page 6

background image

FRAME FABRICATION

(Storefront Typical Installations)

Measure ROUGH OPENING to determine FRAME WIDTH and FRAME HEIGHT

dimensions. Allow 1/4” minimum clearance for shimming and caulking around

perimeter of frame. (FG-3413 Sill Receptor requires minimum 3/8” joint at

head)

Cut material to size per dimensions given below:

Frame Members

Sub-Sill or Sill Receptor:

Frame Width Plus1/4”

Mullion & Mull Fillers:

Frame Height (Rough Opening minus

Head & Sill joints minus Sub Sill height;

FG-3223 minus 3/8”, FG-3413 minus 1/2”)

Horizontal, Sill & Head:

Day Light Opening (D.L.O.)

Horizontal Glazing Beads & Fillers:

D.L.O. minus 1/16”

Accessories

Horizontal Gaskets:

D.L.O. Plus 3/8” per foot.

Vertical Gaskets:

D.L.O. Plus1” Plus 3/8” per foot

Other Members (as required)

Horizontal Glazing Adaptors:

D.L.O. minus 1/16”

Vertical Glazing Adaptors:

D.L.O. Plus 7/8”

Door Jamb:

Rough Opening minus Head Joint

MULL & MULL FILLER

(FRAME HEIGHT)

SUB SILL (FRAME WIDTH Plus 1/4")

HEAD, SILL & HORIZONTAL

(D.L.O.)

HORIZONTAL GLAZING

BEADS

& FILLERS (D.L.O. - 1/16")

FRAME WIDTH

ROUGH OPENING

JAMB

JOINT

( > 1/4")

R

OUGH OPENING

HEAD JOINT

( > 1/4")

SILL JOINT ( > 1/4")

OVERALL FRAME HEIGTH

WITH SUB-SILL

6






S E R I E S 3 0 0 0 T H E R M A L M U L T I P L A N E I N S T A L L A T I O N M A N U A L