background image

DRILL 5/16" WEEP HOLES

LOCATE AT 1/4 POINTS

(DO NOT COVER WITH

SETTING BLOCK)

INSIDE GLAZED, FRONT SET, CAPTURED MULLION ASSEMBLY

FOR SSG SYSTEM

FS-8

PART #: 10223

FS-8

PART #: 10223

*FG-3000-FP-30

PART# 876

FS-9 (TYP.)

MULL CENTERLINE

3/4"

3/4"

FG-3280

FG-3293

FG-3437

FG-3436

APPLY SILICONE

SEALANT TO END

OF HORIZONTALS

AND VERTICALS

AS SHOWN

APPLY SILICONE SEALANT

IN GLAZING REGLET OF

VERTICAL WHERE IT MARRIES

WITH SEALANT APPLIED TO

THE HORIZONTAL

MULL CENTERLINE

3/4"

3/4"

9/16"

1-1/4"

5/8"

TOP OF

HORIZONTAL

1-1/16"

5/8"

NOTCH AT

HEAD

FS-55

REFERENCE PAGE 40 FOR USE OF DJ-7 DRILL FIXTURE.

#11 (0.191 DIA)

TAP HOLE

"F" (0.257 DIA.) DRILL

HEAD & SILL

FG-3278

27






S E R I E S 3 0 0 0 T H E R M A L M U L T I P L A N E I N S T A L L A T I O N M A N U A L