DRILL 5/16" WEEP HOLES LOCATE

AT 1/4 POINTS

(DO NOT COVER WITH SETTING BLOCK)

FG-3280

FG-3280

FG3000-FP-4

BED IN SEALANT

9/16"

1-1/4"

5/8"

*FG3000-FP-30

PART# 876

FS-9 (TYP.)

TOP OF

HORIZONTAL

FG-3334

USE WITH

SSG MULLION

FG-3293

USE WITH

CAPTURED

MULLION

9/16"

1-1/4"

1-3/4"

APPLY SILICONE

SEALANT TO END

OF HORIZONTALS

AND VERTICALS

AS SHOWN

APPLY SILICONE SEALANT

IN GLAZING REGLET OF

VERTICAL WHERE IT MARRIES

WITH SEALANT APPLIED TO

THE HORIZONTAL

1-3/4"

1-1/4"

FG-3436

FS-8

PART #: 10223

FS-8

PART #: 10223

5/8"

1-1/16"

NOTCH AT

HEAD

FS-55

FS-55

NOTE:

*SHEAR BLOCK PACKAGES

INCLUDE FASTENERS

REFERENCE PAGE 40 FOR USE OF DJ-7 DRILL FIXTURE.

#11 (0.191 DIA)

TAP HOLE

"F" (0.257 DIA) DRILL

HEAD & SILL

FG3000-PP-56

END DAM. ALIGN WITH

GLAZING POCKET OF

JAMB AND SEAL TO

TO JAMB AND SILL

FG-3278

INSIDE GLAZED, FRONT SET

JAMB ASSEMBLY FOR SSG SYSTEM

25




